Starting upgrade readiness analysis using SYMC_NBAPP_update_ReadinessAnalyzer-3.1.2-20190715220030.noarch.rpm at Mon Oct 19 15:55:23 2020. - [Warning] Do not reboot the appliance manually while the upgrade is in progress. This tool determines whether a NetBackup appliance is ready for an upgrade. This tool only performs an analysis of the current appliance configuration and has no upgrade capability. >> This tool makes changes to the appliance to prepare it for an upgrade. These changes include, but are not limited to, deleting all existing checkpoints, snapshots, and addon packages. Before you run the analyzer tool, refer to the following article for complete details about all changes that take place after the analysis has completed: https://www.veritas.com/support/en_US/article.100040055. Do you want to continue and run the analyzer tool now? [yes/no] (no) Notice: After successfully upgrading appliances from versions 2.7.x or 3.0, you will observe a major performance impact while an MSDP conversion is in progress. Depending on the MSDP size and the container data segment, this performance impact may last at least 48 hours. For more details, refer to the following article: https://www.veritas.com/support/en_US/article.100041390. Starting the upgrade readiness analysis now. Review the following results for details: - [Info] Checking SDCS IPS policy state.......................................... [OK] - [Info] Cleaning up stale device handles........................................ [OK] - [Info] Checking Appliance restart days......................................... [FAILED] - [Error] V-409-777-1022: Appliance restart days check failed: This Appliance has not been restarted in 14 days. You must first restart this appliance. The restart may require extended time to complete. After the restart has completed, you must launch upgrade readiness analyzer or upgrade again manually. - [Info] Checking System clock................................................... [OK] - [Info] Checking Appliance software version..................................... [OK] - [Info] Checking Appliance hardware model....................................... [OK] - [Info] Checking NetBackup master server version................................ [OK] - [Info] Checking status of the handlehelper process............................. [OK] - [Info] Checking the result of the last backup job.............................. [WARNING] - [Warning] The last backup job was not successful. Make sure that all NetBackup processes are running normally before an upgrade. - [Info] Checking System space................................................... [FAILED] - [Error] V-409-777-1732: Appliance configuration partition extension failed. You must increase this partition to 100 GB to complete the upgrade. For assistance, contact Technical Support. - [Info] Checking MSDP space..................................................... [OK] - [Info] Checking NetBackup catalog space........................................ [OK] - [Info] Checking USB driver..................................................... [OK] - [Info] Checking Open Storage plugin............................................ [OK] - [Info] Checking Disk firmware version.......................................... [OK] - [Info] Checking Appliance storage status....................................... [OK] - [Info] Checking appliance rollback status...................................... [OK] - [Info] No addon is installed. - [Info] Checking appliance memory status........................................ [OK] - [Info] Checking the current appliance BIOS version............................. [OK] The upgrade readiness analysis failed. The appliance cannot be upgraded at this time. Correct all reported errors and run the tool again to verify that all errors have been resolved. - [Info] Running the DataCollect utility to collect all the logs. This may take a few minutes... Finished upgrade readiness analysis at Mon Oct 19 16:27:03 2020.