cancel
Showing results for 
Search instead for 
Did you mean: 

Cleaning Job Failed

syed_jahanzaib
Level 5

I have TS3100 Library. I have designate slot 23 as a cleaning slot. Cleaning tape is inserted in slot 23 as well.

clean-slot-23.PNG

When i try to run the CLEAN job, it gives following error.

 

Final error: 0xe000810d - Physical Volume Library Media not found.
Final error category: Backup Media Errors
Completed status: Failed

error.PNG

barcode.PNG

When I move the CLEANING TAPE manuall to drive, it works fine and clean the tape, but BE not moving it with above error.

Also other tapes are working normal like backup is done ok. only cleaning have isses.

1 ACCEPTED SOLUTION

Accepted Solutions

syed_jahanzaib
Level 5

Finally Solved.

Changed the BARCODE media type as following and now Cleaning works ok :) I guess for IBM TS, LTO CLN is required to be selected.

 

solved.PNG

View solution in original post

10 REPLIES 10

CraigV
Moderator
Moderator
Partner    VIP    Accredited

...have you tried to run the cleaning job from the front panel of the library?

Thanks!

syed_jahanzaib
Level 5

Yes using physical panel of ts3100 cleaning works fine, also via its GUI (ibm ts3100 web gui) , cleaning works fine

only be is not doing th clean job

VJware
Level 6
Employee Accredited Certified

This may help - http://www.symantec.com/business/support/index?page=content&id=TECH68096

syed_jahanzaib
Level 5

Before posting this thread, I tried the link you mentioned, but no use.

VJware
Level 6
Employee Accredited Certified

 Did you try both the alternatives or just one ? If just one, what was tried ?

syed_jahanzaib
Level 5

I tried all the options mentioned in the article TECH68096 and TECH24972 with same error.

 

 

pkh
Moderator
Moderator
   VIP    Certified
Try including Slot 23 into the earlier partition instead of putting it into a separate partition

syed_jahanzaib
Level 5

Didn't worked.


 

CraigV
Moderator
Moderator
Partner    VIP    Accredited

...try removing the partition and job (if scheduled) and recreate.

Thanks!

syed_jahanzaib
Level 5

Finally Solved.

Changed the BARCODE media type as following and now Cleaning works ok :) I guess for IBM TS, LTO CLN is required to be selected.

 

solved.PNG