11-09-2019 06:47 AM
hi
I had sql 2008 and I deleted Then I installed sql 2012
then
1. Launch BEUtility from the Backup Exec directory
2.All Media Servers > right-click the media server name > select New Backup Exec Database Location.
3. Click " Yes" on The Remote Registry Service pop-up message if displayed.
After following the steps, the following error message appears
New Backup Exec Database Location
Error: Failed registry read on server:MSSQLSERVER.
Operation to change location of Backup Exec database to SQL Server instance SYMANTEC-TW ended with errors.
11-11-2019 12:25 AM
while the earlier sql 2008 instance was up, then you could have used beutility
Now since the above source instance is not available, you will need to do the following
1) attach BEDB_dat.mdf and BEDB_log.ldf from BE Install Path\Data in the new instance where you want to host the
backup exec database.
2) Then since the registry will have info about the old sql instance for BE, update them to new. For that refer below article.
https://www.veritas.com/support/en_US/article.100004828
11-19-2019 12:59 AM
Starting SQL service on server: SYMANTEC-TW : MSSQL$BKUPEXEC
Detaching database BEDB from server SYMANTEC-TW.
Stopping SQL service on server: SYMANTEC-TW : MSSQL$BKUPEXEC
Starting SQL service on server: SYMANTEC-TW : MSSQLSERVER
Failed to attach database BEDB to server SYMANTEC-TW.
Operation to change location of Backup Exec database to SQL Server instance SYMANTEC-TW ended with errors.
11-19-2019 01:01 AM
Hi Yousef, I would request you to open a tech support case. Thanks