The alerts display lots of "The driver detected a controller error on \Device\RaidPort1"

Event viewer displays Event ID: 33152 with the follow description

 

Adamm Mover Error: GetDriveInfo Failure!
Error = ERROR_NOT_READY
Drive = "SONY 1"
    {68A83CD8-5268-4AD7-90D4-A28900EFC8C0}
Media = ""
    {00000000-0000-0000-0000-000000000000}
Read Mode: SingleBlock(0), ScsiPass(0)
Write Mode: SingleBlock(1), ScsiPass(1)
 
Tape keeps popping out.
HP ProLiant ML350 G6
Windows 2003 32-bit
SONY AIT 80GB Tape Drive
Tape drive displaying in Device Manager
 
When I run in inventory, it fails.  I restart the Backup Exec services and then I am able to run an inventory.
Attempt to run the an inventory, it fails.  It's like it's not seeing the tape, even when this displays in Device Manager
Tried several other tapes and ran a cleaning tape.
New server, updated the firmware a few months back, appeared to work intermittently, but now it's not working at all.
 
Any suggestions?  Have been round in circiles on this one.
 
Cheers & beers.
2 REPLIES 2

pkh
Moderator
Moderator
   VIP    Certified

Is it connected to a HBA which is supporting RAID?  This configuration is not supported.

teiva-boy
Level 6

Correct, you must use a SCSI card, and not a SCSI RAID card.  This has been the case since the begining of time...