06-06-2019 01:44 AM
Hi
We have Prod and DR clusters with storage level replication. DR has access to the storage as read-only. Now we are adding new CVM/CFS filesystem to Prod and DR. As 'cfsmntadm' updates the VCS configuration, wondering if this can be done at DR as well? (while diskgroup is in deported state).
Platform : VRTSvcs-7.1.0.000-SLES11
Thanks in advance.
06-12-2019 05:25 AM
Depends. If the new CVM/CFS to be added is for local (PROD) cluster only meaning its not to be added in a RVG, you can run cfsmntadm while the dgs on the DR site are not imported otherwise, the dgs on the DR site need to be imported (you should have at least two service groups on each site in which one is for storage only and this service group needs to be online on the DR site as well, in order to bring online the dgs and the vols)).