04-20-2015 01:49 AM
Hi,
Our company just bought Netbackup Appliance and currently in the midst of setting the appliance.
Now there is 2 HBA card used with 4 port already zone in SAN switch.
Storage we used Netapp and all the WWN already insert in initiator group and present it to all related LUN.
I've perform query in the appliance ( Manage>FibreChannel>Scan and Manage>FibreChannel>Show).
The result all is Netapp storage but in the format that I can't understand and doing comparison with the Netapp LUN.
So the question is, how to exactly to verify that the LUN already zoning to the Netbackup Appliance?
Thanks
Solved! Go to Solution.
04-20-2015 10:16 AM
If you drop down to root shell (via Support / Maintenance), does this show anything useful:
# lsscsi -g
04-20-2015 07:41 AM
You should be seeing worldwide names listed of each LUN you zoned in. Can you not match those back to the NTAP LUNs?
04-20-2015 10:16 AM
If you drop down to root shell (via Support / Maintenance), does this show anything useful:
# lsscsi -g