07-20-2020 10:42 AM
I have a query about the difference between a standard software build system and an Appliance
On a stand built server if I wanted to have a look at the emm tables I would use nbdb_unload and I recentyy wanted to do this on an appliance.
the command runs but looking in the output folder there was only an unload.log with an error message inside
either an old version of the server is running or the database "nbdb" was started in an old version of the server
Never seen this error before, how would I go about running this command on appliance.
tried running the command in maintenace mode and with elevate option
07-21-2020 02:12 AM - edited 07-21-2020 02:12 AM
Hello
Hmm stupid question but this NBU appliance is a master server right? My take is, it should dump the tables... as this is 'regular' NBU install with some additional things like CLISH, mongodb, volume manger etc.... but was never trying to unload it there... well I never did it if was not asked by support to do so.
07-21-2020 05:11 AM
yes it is and I agree I would expect it to work, I am wondering if it holds multiple version builds on the appliance might explain the error and it needs to run in the correct instance possibly via an enviroment variable
07-24-2020 12:17 PM
09-17-2020 06:52 AM
as it might help other people, the problem was servers had been merged (I assume catman or its like) and looks like something wasnt right. I didnt see what was done but during a remote session they were able to get it working.