cancel
Showing results for 
Search instead for 
Did you mean: 

Netbackup 7.5.0.1 backups fail with 84 when using acclerator

shashi_pratap
Level 3
Accredited

Hi ,

My NBU environment is consist of a Redhat Master Server , 2 5220 Media Servers , 2 5020 Storage Pools (Pure disk) , backups are working via PDDO.

I recently applied the Netbackup Accelerator license to my environment ,

the first backup went successfully , but the subesquent backups using accelerator is failing with error code 84.

Error bptm (pid 32432) cannot write image to disk , Invalid argument,

Info bpbkar done. status:  84: media write error.

Need your help guys on this. 

1 REPLY 1

Marianne
Level 6
Partner    VIP    Accredited Certified

What is the PureDisk version?

Have you checked/verify that OptimizedImage attribute is enabled on Storage Server? Your error is not the same, but it may be worth checking:   http://www.symantec.com/docs/TECH186768

Also verify that updated device mapping files have been installed on all media servers.

Please post all the info in Details tab of the failed job as well as bptm log. Please post log as File attachment.

Symantec strongly recommends that NBU 7.5.0.4 be used rather than any of the previous 7.5 versions.

Please have a look at 7.5 Late Breaking News: http://www.symantec.com/docs/TECH178334