12-03-2020 09:02 PM
We have the robot tape library, when it require cleaning cartridge I do not see this until I come in and check the jobs with this tape library. I want such an alert notification to come to me by email. How ?
Solved! Go to Solution.
01-14-2021 08:05 PM
Unfortunately, it doesn't work. Alert only flies in after I change the tape to a cleaning cartridge.
12-03-2020 10:35 PM - edited 12-08-2020 10:23 PM
The TapeAlert for cleaning is generated by the tape drive, not NBU.
So, if email alerting is needed, you need to find out if the tape library has that kind of capability.
NBU will only know about the TapeAlert when it needs to use the drive.
So, best practice is to configure automatic cleaning by having one or more cleaning cartridges in the library.
Please have a look at this solution from @mph999 (ignore the Symantec links - they don't work anymore) :
12-04-2020 06:52 AM
Technically 'library based cleaning' is not supported, although people do use it, it is down to the library oif it is able to send emails, although if it is working, there should be no need to do anything other than check the cleaning tapes have not been used up every now and then.
If NBU is used to do the cleaning the same applies - you will know from experience how often the drives need cleaning, so can estimate how long a cleaning tape will last so know approximatly how often you will need to insert new ones - just throw a few tapes in the library and leave it to it.
12-07-2020 12:13 PM
You can parse /usr/openv/netbackup/db/media/errors (or same file on Windows server) and send an alert if you get Tape Alerts like:
0x14: 'Tape drive needs cleaning NOW', 0x15: 'Tape drive needs to be cleaned soon',
12-08-2020 10:32 PM - edited 12-08-2020 10:34 PM
When robot tape library requires cleaning cartridge NBU freezes the current tape. Can I get alert notification to emal about this? Can Ops center send to me such notification ?
12-08-2020 11:38 PM
According to OpsCenter Admin Guide, this is possible:
https://www.veritas.com/support/en_US/doc/27537447-130533036-0/v27807929-130533036
12-10-2020 08:13 PM
Thanks. I shall try it.
01-14-2021 08:05 PM
Unfortunately, it doesn't work. Alert only flies in after I change the tape to a cleaning cartridge.