08-30-2014 11:19 AM
Hi Team,
Tape library on my server showing all drives as AVR mode.
Pls help
Thanks
Solved! Go to Solution.
09-06-2014 12:22 PM
You need to log a call with your hardware vendor. Either an issue with the HBA or the robot:
Sep 6 10:44:37 SRILANKA kernel: scsi 1:0:1:1: timing out command, waited 60s
Sep 6 10:44:37 SRILANKA tldd[25098]: DecodeQuery() Actual status: Unable to sense robotic device
Sep 6 10:44:37 SRILANKA tldd[25098]: TLD(0) unavailable: initialization failed: Unable to sense robotic device
There is nothing that can be done from NBU to fix it.
09-07-2014 12:07 AM
Hi,
As Martin pointed out, there can be a issue a communication issue between the robot control host and device host.
Please check the same.
Thanks
09-07-2014 05:44 AM
I Agree with the Marainne raise call with vendor, Nothing to do from Netbackup end
09-08-2014 01:59 PM
Indeed, this looks like the "hand" or "picker" is now at fault.
09-19-2014 12:45 AM
Almost 2 week of no response!!
Wonder how backups are done under these circumstances....