04-01-2019 02:27 AM
Hello,
The environment is as follow :
NBU master Appliance 3.1.2
BMR Boot Server Windows 2016 running NBU 8.1.2
Windows 2016 registered as a BMR Boot Server ==> OK
ADK as been is correctly on Windows 2016
When creating a x64 NetWork based Shared Resource Tree it failed when installing NBU 8.1.2 Client in SRT.
no error appear in the windows events logs. I just found this message in <InstallDir>\netbackup\logs\bmrsrt logs
"could not copy winsxs directory"
Any idea ?
04-01-2019 02:41 AM
Remove all *.wim files from location " ...\Veritas\NetBackup\BareMetal\server\data"
Try and create SRT again ....
04-01-2019 07:33 AM
Hi @ElGringo !
i had the same problem with a german Windows server. The installer of ADK do not allow to install in English. (it switch automatcally)
My Workaround:
Setup an english Windows in a VM - install NBU - setup BMR - create SRT - export SRT and import on destination server.
ciao
tunix2k