11-16-2017 12:30 AM - edited 11-16-2017 12:33 AM
Hi,
i need to duplicate old backup on LTO4 to LTO6
I go to menu "catalog"=>"duplicate" right clik and i duplicate to my storage unit LTO6
When i do this, i have this error:
16/11/2017 09:17:02 - begin Duplicate
16/11/2017 09:17:03 - requesting resource XXXXX
16/11/2017 09:17:03 - requesting resource 004363
16/11/2017 09:17:03 - reserving resource 004363
16/11/2017 09:17:03 - Error nbjm(pid=5060) NBU status: 830, EMM status: No drives are available
16/11/2017 09:17:03 - Error nbjm(pid=5060) NBU status: 830, EMM status: No drives are available
16/11/2017 09:17:03 - Error nbjm(pid=5060) NBU status: 830, EMM status: No drives are available
16/11/2017 09:17:03 - Error nbjm(pid=5060) NBU status: 830, EMM status: No drives are available
16/11/2017 09:17:04 - end Duplicate; elapsed time: 0:00:02
No drives are available (2001)
I don't understand:
i have my storage unit with my media in.
I can do backup on the LTO6 or LTO4 media (i try this)
But, i can't duplicate my old backup image.
Thanks.
Solved! Go to Solution.
11-21-2017 12:58 PM
hi,
thanks for the answer.
i work with veritas support because the probleme is not present when my LTO4 drive are shared with NDMP (NetApp) device.
If i stop share my LTO4 drive with NDMp : i can't duplicate (zoning with brocade)
when i share my drive : i can duplicate.
If you want i can share what we gonna do with veritas support
11-16-2017 11:56 PM
Do you have tape drives configured that match the density of LTO4 tapes to be duplicated?
You need tape drive(s) with matching density to read the LTO4 tapes.
Please show us output of:
vmquery -m 004363
tpconfig -l
vmoprcmd -d
11-21-2017 12:58 PM
hi,
thanks for the answer.
i work with veritas support because the probleme is not present when my LTO4 drive are shared with NDMP (NetApp) device.
If i stop share my LTO4 drive with NDMp : i can't duplicate (zoning with brocade)
when i share my drive : i can duplicate.
If you want i can share what we gonna do with veritas support
12-08-2017 06:30 AM
well was not a NBU probleme but zonning.