08-15-2012 11:43 PM
Dear all,
Now, my company have plan replace the chasis include robotic for this TS3100. Please guide how to replace it step by step. Note: this TS3100 have 02 tape drive.
Thanks.
Solved! Go to Solution.
08-16-2012 03:07 AM
It will work the same way.
It is sometimes easier, just to delete the devices and re-run the wizard. This is what I tend to do.
Martin
08-16-2012 02:47 AM
tpautoconf -replace_robot robot_number -path robot_path
08-16-2012 03:07 AM
It will work the same way.
It is sometimes easier, just to delete the devices and re-run the wizard. This is what I tend to do.
Martin
08-16-2012 03:15 AM
Dear all,
I mean that i will bring 02 tape drive from the old TS3100 to new TS3100. What thing I must do or only change tape drive is OK ?
Thanks.
08-16-2012 03:36 AM
delete any drives you are removing and re-discover newly connected drive from the wizard or with tpautoconf -a
08-16-2012 03:45 AM
There are several ways to get the same result. I would do the same as Martin suggests.
Stop backups from running. Use the Policy Execution Manager. Using these commands can control whether new backups will run. And perform maintenance while either PEM is terminated or suspended.
Move the tapes to standalone first maybe. So not attached to the robot number.
Delete all tape and robot information.
Delete remove any device info from the OS.
Then connect/ add the new hardware via the device configuration wizard in Netbackup.
Put the tapes into the new slots of the robot chassis
inventory the robot. And run test backup.