I find the problem slight the same problem.
The media id CP0003 , barcode L3CP0003 on robot inventory and media id console. I check the media id length 8 1:2:3:4:5:6 . But the slot number is correct, using robtest and tape library console.
11-24-2017 02:23 AM
Your problem is not really the same.
Your problem, as described over here:
https://vox.veritas.com/t5/NetBackup/error-code-252-and-media-id-not-to-found-in-EMM/td-p/839401/pag...
and
https://vox.veritas.com/t5/NetBackup/Requied-Media-id-not-in-EMM/td-p/842389
is that your library config at some stage was changed to display barcode as
L3XXXXXX
instead of
XXXXXXL3.
As per the posts referenced above, you need to change the library config.