Only one tape drive being used

contra04
Level 5

Hi netbackup 7.0 Windows server 2003 Master & Media server - will not use drive 2 on our quantum px502

When trying a reset, then a drive up, it becomes active for 5 or so minutes or so, then changes the status in activity monitor to DOWN-TLD

 

any ideas?

 

doing an "s d" in robtest, it does not get a source address, but it does report a tape:

 

Robot selected: TLD(0)   robotic path = {4,0,0,0}
 
Invoking robotic test utility:
C:\Program Files\VERITAS\Volmgr\bin\tldtest.exe -rn 0 -r {4,0,0,0}
 
Opening {4,0,0,0}
MODE_SENSE complete
Enter tld commands (? returns help information)
s d
drive 1 (addr 128) access = 1 Contains Cartridge = yes
Source address = 290 (slot 35)
Barcode = L3CLU221
SCSI ID from drive 1 is 1
 
drive 2 (addr 129) access = 1 Contains Cartridge = yes
Barcode = L3CLU215
SCSI ID from drive 2 is 2
READ_ELEMENT_STATUS complete
1 ACCEPTED SOLUTION

Accepted Solutions

contra04
Level 5

TLD(0) cannot dismount drive 2, slot 28 already is full

 

in the windows Application event event log.

 

Used robot to manually move this tape to a free slot  

downed, up -> success !!

View solution in original post

3 REPLIES 3

contra04
Level 5

TLD(0) cannot dismount drive 2, slot 28 already is full

 

in the windows Application event event log.

 

Used robot to manually move this tape to a free slot  

downed, up -> success !!

Marianne
Moderator
Moderator
Partner    VIP    Accredited Certified

Can you see that drive 2 contains a cartridge but the robot does not know which slot the tape came from? Compare with output of drive 1 where the robot knows that the tape came from slot 35.

Easiest maybe to open the robot, manually eject the tape from drive 2 and put it in an empty slot.
Close the robot, wait for it to come online, then inventory in NBU.

Please also add VERBOSE entry to vm.conf (in ...\veritas\volmgr) and restart NetBackup Device Management service.

If drive goes down again, the reason will be logged in Event Viewer Application log. Device errors will be logged in Event Viewer System log.

Marianne
Moderator
Moderator
Partner    VIP    Accredited Certified

Great stuff!! You found the problem yourself! Please run Inventory in NBU to update tape location.

Please ask everyone in your team NOT to open robot and manually insert tapes while there are tapes in any of the tape drives.

As you can see, if another tape is in the slot where unloaded tape needs to go, the drive will be down'ed because the tape cannot be returned to its slot.