Hi All,
How do we need to ensure the drives needs to be replaced and please provide me the steps to check after replacing the drives in Acls & TLD library.
/Raymt
Solved! Go to Solution.
03-18-2012 01:20 AM
9940B and LTO4 are drive types, meaning we still don't anything about your robot/silo or ACSLS.
I will try...
Check that ACSLS sees the drive and correct serial #:
ACSSA> q dr all (note the drive address)
ACSSA> display drive *,*,*,* -f type serial_num (drive address noted above)
On media server, verify that drive is seen at OS level:
# devfsadm (to refresh OS device names)
# /usr/openv/volmgr/bin/tpautoconf -t (look for drive serial # noted above and note OS device name (/dev/rmt/#cbn).
# /usr/openv/volmgr/bin/tpautoconf -report_disc (to report the discrepancy)
# /usr/openv/volmgr/bin/tpautoconf -replace_drive NBU-drive-name -path /dev/rmt/#cbn
Hope this helps. See TN http://www.symantec.com/docs/TECH34296 for more details.
03-17-2012 03:42 AM
Please provide more details.
Netbackup / Backup Exec ?
Version ?
Server Type ? Windows / UNIX
03-17-2012 03:16 PM
03-17-2012 11:04 PM
Netbackup 6.5.6
Solaris 10
StorageTek, Type 9940B, LTO4, LSM
Is that enough....
03-18-2012 01:20 AM
9940B and LTO4 are drive types, meaning we still don't anything about your robot/silo or ACSLS.
I will try...
Check that ACSLS sees the drive and correct serial #:
ACSSA> q dr all (note the drive address)
ACSSA> display drive *,*,*,* -f type serial_num (drive address noted above)
On media server, verify that drive is seen at OS level:
# devfsadm (to refresh OS device names)
# /usr/openv/volmgr/bin/tpautoconf -t (look for drive serial # noted above and note OS device name (/dev/rmt/#cbn).
# /usr/openv/volmgr/bin/tpautoconf -report_disc (to report the discrepancy)
# /usr/openv/volmgr/bin/tpautoconf -replace_drive NBU-drive-name -path /dev/rmt/#cbn
Hope this helps. See TN http://www.symantec.com/docs/TECH34296 for more details.
03-30-2012 04:30 AM
To Add Marianne's post.
Once the drive replaced, Check the serial number whether it's new or old.
In case if it shows old serial number, just make the drive offline and then bring it online.
Eg :
ACSSA>dismount
ACSSA>drive
ACSSA><drive id>
ACSSA>(enter blank)
ACSSA>offline
ACSSA>force
ACSSA>dismount
ACSSA>drive
ACSSA><drive id>
ACSSA>(enter blank)
ACSSA>online
ACSSA>force
Now, check the drive serial number.. It should show new one and you can test backup.
Note : If you are using VTL and if it's backend drive then you should drop and add from VTL level.