symsonu
Level 6

backup jobs are failing as below

 

6/26/2014 00:26:29 - estimated 8946870 kbytes needed
06/26/2014 00:26:29 - Info nbjm (pid=3930) started backup (backupid=xxxxbp_1403735189) job for client xxxxxbp, policy xxx_i386_DATA_xxx01xxxbp_xxx01sybbp, schedule Daily_Incr on storage unit xxxxx01-hcart-robot-tld-0
06/26/2014 00:26:30 - Info bpbrm (pid=632) xxxxxxxbp is the host to backup data from
06/26/2014 00:26:30 - Info bpbrm (pid=632) reading file list from client
06/26/2014 00:26:30 - started process bpbrm (pid=632)
06/26/2014 00:26:30 - connecting
06/26/2014 00:26:31 - Info bpbrm (pid=632) starting bpbkar on client
06/26/2014 00:26:31 - Info bpbkar (pid=0) Starting bpstart_notify script
06/26/2014 00:26:31 - connected; connect time: 0:00:00
06/26/2014 00:26:40 - Info bpbkar (pid=0) Finished bpstart_notify script
06/26/2014 00:26:40 - Info bpbkar (pid=1620) Backup started
06/26/2014 00:26:40 - Info bpbrm (pid=632) bptm pid: 667
06/26/2014 00:26:41 - Info bptm (pid=667) start
06/26/2014 00:26:41 - Info bptm (pid=667) using 65536 data buffer size
06/26/2014 00:26:41 - Info bptm (pid=667) setting receive network buffer to 262144 bytes
06/26/2014 00:26:41 - Info bptm (pid=667) using 30 data buffers
06/26/2014 00:26:41 - Info bptm (pid=667) start backup
06/26/2014 00:26:41 - Info bptm (pid=667) backup child process is pid 669
06/26/2014 00:26:41 - Info bptm (pid=667) media id 5941L4 mounted on drive index 0, drivepath /dev/rmt/1cbn, drivename HP.ULTRIUM4-SCSI.000, copy 1
06/26/2014 00:26:41 - mounted 5941L4
06/26/2014 00:26:41 - positioning 5941L4 to file 737
06/26/2014 00:26:43 - positioned 5941L4; position time: 0:00:02
06/26/2014 00:26:43 - begin writing
06/26/2014 00:31:11 - Error bpbrm (pid=632) db_FLISTsend failed: Unable to connect to the database (2505)
06/26/2014 00:31:13 - Error bptm (pid=667) media manager terminated by parent process
06/26/2014 00:35:18 - Info bpbkar (pid=1620) done. status: 2505: Unable to connect to the database
06/26/2014 00:35:18 - end writing; write time: 0:08:35
Failed to get status code information (2505)

 

what is the solution for error code 2505 ?

 

I can see few jobs failed with status 2505 and few with 252 ?

please help.

 

Regards

S.

1 ACCEPTED SOLUTION

Accepted Solutions

revarooo
Level 6
Employee

Come across this issue multiple times. It is fixed in NetBackup 7.5.0.7

Sybase does not respond for a brief moment causing bpdbm updates to fail resulting in a 2505.

Tuning the higher cache limit -ch in the server.conf can help, but doesn't always.

 

Upgrade to 7.5.0.7 will fix this as bpdbm has been recoded to attempt to talk to sybase more than once before failing.

 

View solution in original post

13 REPLIES 13

RamNagalla
Moderator
Moderator
Partner    VIP    Certified

tell us more about your infrastcture..

what is the OS and netbackup verisons in Master server..

it looks like you need to tune the server kernal parameters..

have a look into below T/N.

http://www.symantec.com/business/support/index?page=content&id=TECH203316

http://www.symantec.com/business/support/index?page=content&id=TECH213131

Marianne
Moderator
Moderator
Partner    VIP    Accredited Certified

Have a look at the following:

https://www-secure.symantec.com/connect/forums/after-upgrade-7503-71-status-2505-and-252 

http://www.symantec.com/docs/TECH203316

http://www.symantec.com/docs/TECH210207 

The 2nd TN is probably applicable here as both error codes are listed.

Issue is caused by insufficient semaphore tuning.

See the TN mentioned under 'Related Articles':

As well as NBU 7.5 Performance Tuning doc: 
Updated NetBackup Backup Planning and Performance Tuning Guide for Release 7.5 and Release 7.6

sri_vani
Level 6
Partner

It would be helpful if you could provide us more details to troubleshoot on the issue

What is ur Master/media/client- OS and NBU versions?

How many backups are impacted and what kind of backups? bptm and bpdbm logs will log us more details

When verified I found below notes on this error: Please go through it(Status code 2505 along with 252)

 

http://www.symantec.com/business/support/index?page=content&id=TECH203316

The error is typically when the RHEL system is the NetBackup (NBU) master server. This error can be caused by a lack of semaphore tuning within the kernel.  This error cannot be resolved by NetBackup.

 

Solution

In this case, the semmni value was insufficient at 128. By increasing this value to 1024, the ODBC connection was successful and NetBackup was then able to run successfully.

 

symsonu
Level 6

where is the bpdbm logs located ?

 

Do I need to create directory for it? and does we need to restart netbackup services after creation of firectory ?

 

 

Regards

S.

sri_vani
Level 6
Partner

Unix: usr/openv/netbackup/logs/bpdbm/

Windows:Installationpath/netbackup/logs/bpdbm/

It is best to stop and restart the NetBackup services after making any changes .

revarooo
Level 6
Employee

Come across this issue multiple times. It is fixed in NetBackup 7.5.0.7

Sybase does not respond for a brief moment causing bpdbm updates to fail resulting in a 2505.

Tuning the higher cache limit -ch in the server.conf can help, but doesn't always.

 

Upgrade to 7.5.0.7 will fix this as bpdbm has been recoded to attempt to talk to sybase more than once before failing.

 

Marianne
Moderator
Moderator
Partner    VIP    Accredited Certified

Just for the record - bpdbm log folder needs to be created on the master server under /usr/openv/netbackup/logs. 

NBU needs to be restarted for log to take effect.

revarooo
Level 6
Employee

Don't bother with the logs, go straight to 7.5.0.7- you won't have this problem after.

symsonu
Level 6

our netbackup version is 7.5.0.4

and I can see from system file in solaris the below values are set

set semsys:seminfo_semmni=1024

set msgsys:msginfo_msgmni=256

set shmsys:shminfo_shmmni=256

set shmsys:shminfo_shmmax=16759808

 

we are not using projects and above values are set in system file in solaris.

 

# cat  /usr/openv/var/global/server.conf

 -n NB_cpombs01

   -x tcpip(LocalOnly=YES;ServerPort=13785)  -gp 4096 -gd DBA -gk DBA -gl DBA -ti 0 -c 100M -ch 1024M -cl 100M -zl -os 1M -m -o /usr/openv/db//log/server.log

 -ud

 

 

Regards

S.

Marianne
Moderator
Moderator
Partner    VIP    Accredited Certified

Please follow revaroo's advice and upgrade to 7.5.0.7.

sri_vani
Level 6
Partner

yes

NBU4Life
Level 1

Getting 2505s and 252s on VXOS - 5350 FLEX appliances, any body know the tuning recommendations for this system? 

StefanosM
Level 6
Partner    VIP    Accredited Certified

please open a new case.
Had you add ips to the hosts file manually?