nbrestorevm -ir_listvm failed to get instant recovery identifier ....cannot connect on socket 25

NEBC_Admin
Level 3

i have started VM instant recovery from VMware Web plugin and it is working properly and machine is up and running.

i have successfully migrated the VM to another datastore on VMware.

now i need to complete the VM instant recovery job on the Netbackup Master server.

when i run command: nbrestorevm –ir_listvm to get the Instant Recovery ID, the following error is the output

cannot connect on socket (25) to the Master server name

which is weird as i am running this command on the master server.

1 ACCEPTED SOLUTION

Accepted Solutions

Michal_Mikulik1
Moderator
Moderator
Partner    VIP    Accredited Certified

Hello,

in case of Windows Master, verify your cmd is launched via Run as Admin.

If NBAC is implemented, verify that you are also logged in via bpnbat -login.

Regards

Michal

View solution in original post

3 REPLIES 3

Michal_Mikulik1
Moderator
Moderator
Partner    VIP    Accredited Certified

Hello,

in case of Windows Master, verify your cmd is launched via Run as Admin.

If NBAC is implemented, verify that you are also logged in via bpnbat -login.

Regards

Michal

Mike_Gavrilov
Moderator
Moderator
Partner    VIP    Accredited Certified

Try to run it from the media server you used for the restore

Thanks Michal. That works perfectly to me after login on CMD with bpnbat -login.

all commands worked properly after that.


@Michal_Mikulik1 wrote:

Hello,

in case of Windows Master, verify your cmd is launched via Run as Admin.

If NBAC is implemented, verify that you are also logged in via bpnbat -login.