netapp backup is failing with error 84 and showing message "FREEZING media id XXXXX, too many data blocks written, check tape/driver block size configuration"

One netapp volume(NDMP) backup is failng with error 84 and in details logs it is showing the message " FREEZING media id XXXXX, too many data blocks written, check tape/driver block size configuration" we are using netbackup 7.0.1.2 (OS-Solaris10).

3 Replies
Highlighted

check this technote

Highlighted

Go with 7.1.0.3

The fix is in 7.1.0.3 as well:

http://www.symantec.com/docs/TECH174256

Highlighted

there must be drive

there must be drive flactuation. Also check drive readibilty. try to clean the drive.