Server crash when import SAN disk

bordio27
Level 4

Hi everyone

 I have an issue with a replicated SAN disk on a secondary VVR server.

While I try to import the disk, the Windows Server 2012 crashes and BSOD happens with an error related to ntfs.sys

The import command:

vxdg -g diskgroup import Harddisk1

Trying to find logs about import command to see errors, but I cannot find anything

How can I do debug?

Software version:

VxPolicyManager WINNT.7.0.0.129
actionprovider 1.0.0.0
alert WINNT.7.0.0.129
cluster WINNT.7.0.0.129
controlpanel 1.0.0.0
ddlprov WINNT.7.0.10002.129
disk WINNT.7.0.0.129
fastfileresync WINNT.7.0.0.129
fsys WINNT.7.0.0.129
ftdisk WINNT.7.0.0.129
iscsi WINNT.7.0.0.129
logger 3.4
mount WINNT.7.0.0.129
mpioprov WINNT.6.1.0.445
pnp WINNT.7.0.0.129
scheduler WINNT.7.0.0.129
sysprov WINNT.7.0.10002.129
vdsprov WINNT.7.0.0.129
vmstat WINNT.7.0.0.129
vssprov WINNT.7.0.0.129
vvr WINNT.7.0.10002.129
vxvm WINNT.7.0.00000.129

Thank you

db

1 ACCEPTED SOLUTION

Accepted Solutions

bordio27
Level 4

Ok, I solved opening a case to the Veritas support

They recreated the disk group and reconfigured the replication

db

 

View solution in original post

1 REPLY 1

bordio27
Level 4

Ok, I solved opening a case to the Veritas support

They recreated the disk group and reconfigured the replication

db