How to resolve CPI ERROR V-9-0-0 arch_sys undefined
Hi, I'm installingStorage Foundation and High Availability (SFHA) on two nodes. Everything is configured correctly based on the given document. But, in the middle of installation, it returns this error: CPI ERROR V-9-0-0 arch_sys undefined I don't know how to resolve, and google didn't give any clue about that. Can anyone suggest what should I do to fix that? here's my machine on node A: Linux xxxxxx 2.6.18-274.el5 #1 SMP Fri Jul 8 17:36:59 EDT 2011 x86_64 x86_64 x86_64 GNU/Linux Regards, AntonSolved3.6KViews0likes9Commentssymantec AppHA problem
Hi my esxi version is 5.5 u2 and my vcenter version is 5.5 u1 now i have downloaded VCS 6.1 & High availability console 6.1 & application HA 6.1 i have reade all of documents but now i am so confused pleas say me ehat is the order of installing symantec product and say me please each of these product on what vm do i have to install? for example on vcenter server or ........ for example i have installed ha console on a seprate machine but when connect to vcenter on product there is no vm i have attached files i dont know what is my problem so thanks babakSolved3.4KViews0likes14CommentsApplication ha6.1 suppport matrix for vmware rethat 6 guest
hi, I have installed symantec ha console 6.1 on windows platform . Isthis the newest verion for windows platform? Iknow linux platform you can install to 6.2 version. what issuppport matrix for vmware rethat 6 guest OS for application ha? Where can I find this information? Thanks AllenSolved3.4KViews0likes1Commentdifferences between Symantec ApplicationHA for Vmware and Symantec High Availability Solutions Guide for VMware
hi, Can anyone explain the main differences between Symantec ApplicationHA for Vmware and Symantec High Availability Solutions Guide for VMware? Kind of confuse about these two products. Thanks AllenSolved2.4KViews1like4Commentsfailed to bring up HeartBeat interface with GAB config
Dear Experts, I'm facing an issue here in cluster setup 8+2 I have managed to create 1+1 cluster and when trying to add the 3rd node I got stuck in gabconfig step below is the /var/adm/messages Jun 21 22:49:50 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartCore: Starting hardware (clients None) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: Phy capabilities (1) (supported 0x00000f50 0x00000000) (link_config 0x01000000 0x00000000) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.warning] WARNING: bnxe3: Phy 10000fdx requested but not supported Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: Phy requesting link config of 0x00000006 Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: 10Gb Full Duplex Rx Flow ON Tx Flow ON Link Up Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartCore: Hardware started (clients None) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartL2: L2 started (clients L2) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopL2: Stopping L2 (clients L2) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopCore: Stopping hardware (clients None) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: Link Down Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopCore: Hardware stopped (clients None) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopL2: L2 stopped (clients None) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartL2: Starting L2 (clients None) Jun 21 22:49:51 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartCore: Starting hardware (clients None) Jun 21 22:49:52 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: Phy capabilities (1) (supported 0x00000f50 0x00000000) (link_config 0x01000000 0x00000000) Jun 21 22:49:52 MM-BL2 bnxe: [ID 801725 kern.warning] WARNING: bnxe3: Phy 10000fdx requested but not supported Jun 21 22:49:52 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: Phy requesting link config of 0x00000006 Jun 21 22:49:52 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: 10Gb Full Duplex Rx Flow ON Tx Flow ON Link Up Jun 21 22:49:52 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartCore: Hardware started (clients None) Jun 21 22:49:52 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStartL2: L2 started (clients L2) Jun 21 22:49:53 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopL2: Stopping L2 (clients L2) Jun 21 22:49:53 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopCore: Stopping hardware (clients None) Jun 21 22:49:53 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: Link Down Jun 21 22:49:53 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopCore: Hardware stopped (clients None) Jun 21 22:49:53 MM-BL2 bnxe: [ID 801725 kern.info] NOTICE: bnxe3: BnxeHwStopL2: L2 stopped (clients None) knowing that I have the same network profiles interfaces for all blades ( HP Proliant blades ) any ideas how this can be fixed ? BR Mahmoud2KViews0likes1CommentOracle upgrade on veritas cluster 5.1 SP1
Hi , We are planning to upgrade oracle from 10.2.0.4 to 11.2.0.3 on windows 2008 environment. We have SAP Portal Ehp1 for that uses this database. both the SAP and oracle group are clustered with the VCS version 5.1 SP1 over 2 nodes. Would like to know the process for upgrading the oracle in this clustered environment. Do we need to install & upgrade only on one node or do it on both the nodes/ Kindly share relevant documentation for this purpose. regards, SreekSolved1.9KViews0likes3CommentsFailover to secondary system upon ungraceful shutdown
I have configured a cluster with monitored services and it works as intended with one exception. If I hard/ungraceful power down, cluster does not fail over to the working system and start the services automatically. Below is the script that I use to create the cluster. I am hoping I just missed a setting. hastatus displayes the following last message App_Cluster SYSTEM_1 *FAULTED* OFFLINE If i bring the downed system backup up then the system decides to fail over the the other box. This is the script that I use to configure the cluster haconf -makerw haclus -modify PrintMsg 0 haclus -modify UserNames admin xxxxxxxxxxxxx haclus -modify ClusterAddress "127.0.0.1" haclus -modify Administrators admin haclus -modify SourceFile "./main.cf" haclus -modify ClusterName CMSApp hasys -add SYSTEM_1 hasys -modify SYSTEM_1 SourceFile "./main.cf" hasys -add SYSTEM_2 hasys -modify SYSTEM_2 SourceFile "./main.cf" hagrp -add APP_CLUSTER hagrp -modify APP_CLUSTER SystemList SYSTEM_1 0 SYSTEM_2 1 hagrp -modify APP_CLUSTER VCSi3Info "" "" -sys SYSTEM_1 hagrp -modify APP_CLUSTER AutoStartList SYSTEM_1 SYSTEM_2 hares -add Virtual_IP IP APP_CLUSTER hares -local Virtual_IP Device hares -modify Virtual_IP Device eth0 -sys SYSTEM_1 hares -modify Virtual_IP Device eth0 -sys SYSTEM_2 hares -modify Virtual_IP Address "192.168.0.3" hares -modify Virtual_IP NetMask "255.255.255.0" hares -modify Virtual_IP PrefixLen 1000 hares -modify Virtual_IP Enabled 1 hares -add Network_Card NIC APP_CLUSTER hares -local Network_Card Device hares -modify Network_Card Device eth0 -sys SYSTEM_1 hares -modify Network_Card Device eth0 -sys SYSTEM_2 hares -modify Network_Card PingOptimize 1 hares -modify Network_Card Mii 1 hares -modify Network_Card Enabled 1 thxSolved1.8KViews1like8CommentsSolaris 10 + Zones + ZFS + VCS
Hi all, I don't have a lot of experiences on VCS I have 2 servers on Solaris 10 update 11, installed on ZFS (rpool), and I want to do a Cluster for an application APP Node A = zonea (zonepath for zonea is ZFS / local disk ZFS ) Node B = zoneb (zonepath for zoneb is ZFS / loacl disk ZFS ) The application APP ( FailOver) have to move between zonea and zoneb With that configuration it is possible to do this ? If not what is the best practices : salaris 10 + zfs local zones + VCS 6.0.1 ? Best RegardsSolved1.7KViews0likes1Comment