VxVM vxdisksetup ERROR V-5-2-5241 Cannot label as disk geometry cannot be obtained.
Dear Community I m facing the current issue, can you please support /etc/vx/bin/vxdisksetup -i emcpower0 format=sliced emcpower0cs2 VxVM vxdisksetup ERROR V-5-2-5241 Cannot label as disk geometry cannot be obtained. bash-3.2# powermt display dev=all Pseudo name=emcpower0a CLARiiON ID=xxxxxxx [MMSUN] Logical device ID=6006016043B3340080D4F1C7A808E411 [LUN 100] state=alive; policy=CLAROpt; priority=0; queued-IOs=0; Owner: default=SP A, current=SP B Array failover mode: 1 ============================================================================== --------------- Host --------------- - Stor - -- I/O Path -- -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0 c3t0d0s0 SP B0 active alive 0 0 3072 pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0 c4t0d0s0 SP A0 active alive 0 0 Pseudo name=emcpower2a CLARiiON ID=xxxxxxxx [MMSUN] Logical device ID=6006016043B3340081D4F1C7A808E411 [LUN 101] state=alive; policy=CLAROpt; priority=0; queued-IOs=0; Owner: default=SP B, current=SP B Array failover mode: 1 ============================================================================== --------------- Host --------------- - Stor - -- I/O Path -- -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0 c3t0d1s0 SP B0 active alive 0 0 3072 pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0 c4t0d1s0 SP A0 active alive 0 0 Pseudo name=emcpower1a CLARiiON ID=xxxxxxxx [MMSUN] Logical device ID=6006016043B3340082D4F1C7A808E411 [LUN 102] state=alive; policy=CLAROpt; priority=0; queued-IOs=0; Owner: default=SP A, current=SP A Array failover mode: 1 ============================================================================== --------------- Host --------------- - Stor - -- I/O Path -- -- Stats --- ### HW Path I/O Paths Interf. Mode State Q-IOs Errors ============================================================================== 3073 pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0 c3t0d2s0 SP B0 active alive 0 0 3072 pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0 c4t0d2s0 SP A0 active alive 0 0 bash-3.2# format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <LSI cyl 36348 alt 2 hd 255 sec 63> /pci@0,0/pci8086,3c08@3/pci1000,9262@0/sd@0,0 1. c0t1d0 <LSI cyl 36349 alt 2 hd 255 sec 63> /pci@0,0/pci8086,3c08@3/pci1000,9262@0/sd@1,0 2. c0t2d0 <LSI cyl 36349 alt 2 hd 255 sec 63> /pci@0,0/pci8086,3c08@3/pci1000,9262@0/sd@2,0 3. c0t3d0 <LSI cyl 36349 alt 2 hd 255 sec 63> /pci@0,0/pci8086,3c08@3/pci1000,9262@0/sd@3,0 4. c3t0d0 <DGC -RAID 10 -0223 cyl 65268 alt 2 hd 255 sec 63> /pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601683ba074ee,0 5. c3t0d1 <DGC -RAID 10 -0223 cyl 65268 alt 2 hd 255 sec 63> /pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601683ba074ee,1 6. c3t0d2 <DGC -RAID 10 -0223 cyl 13052 alt 2 hd 255 sec 63> /pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601683ba074ee,2 7. c4t0d0 <DGC -RAID 10 -0223 cyl 65268 alt 2 hd 255 sec 63> /pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601603ba074ee,0 8. c4t0d1 <DGC -RAID 10 -0223 cyl 65268 alt 2 hd 255 sec 63> /pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601603ba074ee,1 9. c4t0d2 <DGC -RAID 10 -0223 cyl 13052 alt 2 hd 255 sec 63> /pci@79,0/pci8086,3c02@1/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601603ba074ee,2 10. emcpower0a <DGC -RAID 10 -0223 cyl 65268 alt 2 hd 255 sec 63> /pseudo/emcp@0 11. emcpower1a <DGC -RAID 10 -0223 cyl 13052 alt 2 hd 255 sec 63> /pseudo/emcp@1 12. emcpower2a <DGC -RAID 10 -0223 cyl 65268 alt 2 hd 255 sec 63> /pseudo/emcp@2Solved4KViews2likes4CommentsProduct compatibility matrix for Storage foundation and cluster server
I am part of a services Org. in IBM that delivers solutions on POWER AIX systems. We have some very large enterprises which use both VCS and VSF products. I am trying to find an updated product compatibility matrix showing the following: List which VCS and VSF version and release levels are supported or compatible with current versions of PowerVM Virtual IO Server (version and release). VSF documentation indicates support for "OS Logical volume managers" (LVM and PowerVM Live Partition mobility (LPM). I would like to know any AIX, VCS or VSF version and release dependencies to enable the OS LVM and PowerVM LPM functions within Storage foundation and Cluster server.Solved2KViews1like4CommentsVXVM needs license ... please help
Dear all, i have installed VXVM 5.0 basic on my Virtual machine (Solaris 5.10) when i tried to mount the volume, i have received this error "UX:vxfs mount: ERROR: V-3-25255: mount: You don't have a license to run this program" is there any way out? i was looking in a forum, which described to check pkginfo -l VRTSvxfs | grep STATUS complete install ls -lad /devices/pseudo/vxportal it does not find these directories.... then i performed devfsadm -v -i vxportal it failed with exit status 1Solved1.9KViews0likes7CommentsReplacing a shared disk group for stroage migration
Can any one post the steps to replacing a disk that has shared dg group on CFS cluster on HP unix service guard with the below existing attributes. layout=mirror mirror=2 mirror=enclr enclr=emc0 enclr=emc1 logtype=dco dcoversion=20 ndcomirror=2 dr1=on fastresync=onSolved1.8KViews0likes5Commentslun over 2TB got error status from vxdisk list
Hi, I have tried to bring up this lun for 2 days, and got nearly no progress, sometimes the lun can be online, but if I try to use vxdisksetup to setup it, it would become error again, I am really despairing, I hope someone can help me to solve this, thank u. HBWHCG01:/# vxdisk list DEVICE TYPE DISK GROUP STATUS c0t0d0s2 auto:none - - online invalid emcpower0s2 auto - - error emcpower1s2 auto:none - - online invalid emcpower2s2 auto:none - - online invalid emcpower3s2 auto:none - - online invalid emcpower4s2 auto:none - - online invalid emcpower5s2 auto:none - - online invalid emcpower6s2 auto:none - - online invalid HBWHCG01:/# format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c0t0d0 <DEFAULT cyl 36348 alt 2 hd 255 sec 126> /pci@0,0/pci8086,3408@1/pci1000,9262@0/sd@0,0 1. c1t0d0 <DGC-RAID 10-0223-2.32TB> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,0 2. c1t0d1 <DEFAULT cyl 3913 alt 2 hd 255 sec 63> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,1 3. c1t0d2 <DEFAULT cyl 6524 alt 2 hd 255 sec 63> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,2 4. c1t0d3 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,3 5. c1t0d4 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,4 6. c1t0d5 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,5 7. c1t0d6 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0/fp@0,0/disk@w500601613ba07373,6 8. c2t0d0 <DGC-RAID 10-0223-2.32TB> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,0 9. c2t0d1 <DEFAULT cyl 3913 alt 2 hd 255 sec 63> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,1 10. c2t0d2 <DEFAULT cyl 6524 alt 2 hd 255 sec 63> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,2 11. c2t0d3 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,3 12. c2t0d4 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,4 13. c2t0d5 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,5 14. c2t0d6 <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pci@0,0/pci8086,340c@5/pci111d,806c@0/pci111d,806c@2/pci1077,172@0,1/fp@0,0/disk@w500601693ba07373,6 15. emcpower0a <DGC-RAID 10-0223-2.32TB> /pseudo/emcp@0 16. emcpower1a <DEFAULT cyl 3913 alt 2 hd 255 sec 63> /pseudo/emcp@1 17. emcpower2a <DEFAULT cyl 6524 alt 2 hd 255 sec 63> /pseudo/emcp@2 18. emcpower3a <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pseudo/emcp@3 19. emcpower4a <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pseudo/emcp@4 20. emcpower5a <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pseudo/emcp@5 21. emcpower6a <DEFAULT cyl 1020 alt 2 hd 64 sec 32> /pseudo/emcp@6 Specify disk (enter its number): 15 selecting emcpower0a [disk formatted] FORMAT MENU: disk - select a disk type - select (define) a disk type partition - select (define) a partition table current - describe the current disk format - format and analyze the disk fdisk - run the fdisk program repair - repair a defective sector label - write label to the disk analyze - surface analysis defect - defect list management backup - search for backup labels verify - read and display labels inquiry - show vendor, product and revision volname - set 8-character volume name !<cmd> - execute <cmd>, then return quit format> p PARTITION MENU: 0 - change `0' partition 1 - change `1' partition 2 - change `2' partition 3 - change `3' partition 4 - change `4' partition 5 - change `5' partition 6 - change `6' partition expand - expand label to use whole disk select - select a predefined table modify - modify a predefined partition table name - name the current table print - display the current table label - write partition map and label to the disk !<cmd> - execute <cmd>, then return quit partition> p Current partition table (original): Total disk sectors available: 4991205341 + 16384 (reserved sectors) Part Tag Flag First Sector Size Last Sector 0 usr wm 34 2.32TB 4991205341 1 unassigned wm 0 0 0 2 unassigned wm 0 0 0 3 unassigned wm 0 0 0 4 unassigned wm 0 0 0 5 unassigned wm 0 0 0 6 unassigned wm 0 0 0 8 reserved wm 4991205342 8.00MB 4991221725Solved1.8KViews0likes12CommentsCVM/CFS on Solaris
Dear All, I would like to create a VCS cluster of 2 nodes that will have the CFS mounted on both of them. Once the CFS is mounted into the cluster I want to get it shared to the system that is not part of VCS cluster. My question is it possible if not what could be the best way. Objective for this I want to test performance (read/write) on CFS as compare to NFS, QFS. I will appreciate your input.Solved1.5KViews1like5CommentsVxVM vxconfigd ERROR V-5-1-8561 ddl_fill_dmp_info:
Hi community, Recently there was a project to add a new EMC AX4-5 enclosure on top of the existing AX4-5 Enclosure (a new array of disks). Current cluster is a 6 blade cluster where all blades share the same LUNs (partitions) using VCSFS and PowerPath. After adding the new LUNs and then running on the master blade of the cluster and scanning the devices (devfsadm -Cv) then the following error was encountered: # vxdctl enable VxVM vxdctl ERROR V-5-1-307 vxconfigd is not running, cannot enable # vxconfigd -k VxVM vxconfigd ERROR V-5-1-8561 ddl_fill_dmp_info: Path 0x4080280 not found in devlist: Error 0 VxVM vxconfigd ERROR V-5-1-1589 enable failed: System error occurred in the client Error 0; aborting Veritas also creates a core dump file, Here is the pstack output: # pstack core core 'core' of 64: vxconfigd -x syslog -m boot fed656ba strcmp (84215b0, bcddc5c) + 10a 08120aaf dmp_getpathindex (8047b3c, 84215b0, 9fb5000) + 77 08120492 dmp_countenclr_lun (8047b3c, 804729a, 9fb5000) + 72 0811f6d3 dmp_dumpenclr (8047b3c, 9fc0408, 9fb5000) + fb 0811f586 dmp_append (8047b3c, 9fc0408, 0, 2710, 9fb5000) + 12a 0811f120 config_dmpdump (8883110, 9fc0408, 3e000000) + 1d8 081259f0 config_all (8883110, 3e000000, 1) + 57c 08125397 req_dg_getconfig_all (8883110, 82bec48) + 3f 0812f55b request_loop (8047e68, 8047de8, feffb818, 1, feffb818, 3b80000) + 76b 0810a2fc main (5, 8047e2c, 8047e44) + b74 080771d2 ???????? (5, 8047ed0, 8047eda, 8047edd, 8047ee4, 8047ee7) Engine log: 2011/12/08 09:31:27 VCS ERROR V-16-10001-1004 CVMVxconfigd:???:monitor:Core file saved once already 2011/12/08 09:31:28 VCS INFO V-16-2-13001 Resource(cvm_vxconfigd): Output of the completed operation (monitor) /core: ELF 32-bit LSB core file 80386 Version 1, from 'vxconfigd' Any ideas ? P.S. All logical paths are shown active by running "powermt display dev=all" towards the EMC array. Thanks, Florin.1.2KViews0likes4CommentsSFRAC
Hello all, Need your inputs to see what we really need? :-) Environment: Oracle RAC 11Gr2 on Linux with Netapp backup. Need to write to 2 netapp at the same time for data mirroring (Frame mirroring). We have been told Oracle ASM will not be able to do it. Only Veritas Volume Manager can do the disk mirroring. Sale people said we need SFRAC for Oracle RAC. But we looked into SFRAC5.1, we see it has VCS (Veritas Cluster) also. Curious to know we already running oracle RAC, why do we need VCS?? Tks JohnSolved1.1KViews0likes7Comments