After Upgrade to v6: monitor:Blockmountpointaccess not configured
Hi there We upgraded our Test single Node cluster to the version 6 with cp2. After the installation and reboot all of the mountv resource are in a failed state. in the mountv_a.txt logfile i found this line: monitor:Blockmountpointaccess not configured Any suggestions how to fix that? ThanksSolved2.5KViews6likes3CommentsHELP-HOW TO CONFIGURE VVR to two Servers
The purpose of this message is to request support interest in the configuration of two servers (Primary) HP ProLiant DL385p Gen7 virtualized, and a (Secondary) HP ProLiant DL380p Gen7, both with Platform Windows Server 2008, Standard x64 version, 64bit, to be connected for synchronous replication. Currently have installed on both computers Software Symantec Veritas Storage Foundation VSF, V6.0, in where Volume Replicator is an option that we want to achieve for both to maintain a daily backup replication or synchronously via IP network. I shall be waiting for your comments, Best regards, **************************************************************************************************************** El propósito de este mensaje es el interés de solicitarle apoyo en la configuración en dos Servidores (Primario)HP ProLiantDL385p Gen7 virtualizado, y un (Secundario)HP ProLiantDL380p Gen7, ambos con Plataforma Windows Server 2008, version Standard x64, 64bit, conectados, para replicación sincrónica. Actualmente se tienen instalados en ambos equipos elSoftware Symantec Veritas Storage Foundation VSF, V6.0, en dondeVolume Replicatores una opción con la que queremos lograr que ambos mantengan una replicación diaria o backup de forma sincrónica vía red IP. Quedaré a la espera de sus comentarios, Saludos Cordiales,SolvedCannot log a technical support case
Hi, My customer has a valid support contract for Symantec VRTS Storage Foundation 6.0 for Windows. She has registered her porduct licences with her SymAccount. When she tries to log a support case online through https://my.symantec.com/webapp/faces/custcare?casetype=cc, she gets the following error: "Please fill a valid Product Version". I also tried it with her credentialsmanty timestrying different forms of product and version information but we could not achive to create our support case. I think ıt should not be so hard for creating a support case for a product with a valid support aggreement. I appreciate if anyone can help us to find the correct "Product Version" for logging our support case. best regards, SukruSolved1.6KViews2likes4CommentsInstallation of Storage Foundation on Win 2003 Ent. R2
Hi, We have two servers with two non-standerd application running. The Operating System - Windows 2003 Ent. R2 FC based storage connected with both the servers. Now we wants a DR site with host to host replication ... Will this solution work ..........any caution need to take care... I came accross some docs..that the C drive need to be in adifferent arry... IS IT.. Is there any thing else need to take care... Can we also do through Backup Exec to take a backup and create a DR site ...or something.. Please, help.. :) Thanks.how to check DMP in VCS is working?
Hi, We installed Storage foundation HA 6.1 with DMP set with all option marked. Before that we had the EMC power-path application, where we could see that multipathing sees all disks from all available paths. now we have the SFHA DMP option installed, But I can't figure out where do I see that the system see all disks through all switches. Any way to check this via GUI or command line without having to manually disconnect disks to check it? Thanks, SarahSolved3.2KViews1like2CommentsHow to get Volume information?
Hi all, We are in the proces of fully automating extending a volume. I need some information on which commands to do this with. To extend the correct disks I need the SerialNumbers of those disks so Storage management knows which luns to extend in the SAN environment. Does anyone know howtofind these numbers through commands? Ivo3.6KViews1like9Commentsglobal group takes a long time to go online
Hi everyone, I'm facing the following problem related with the time to go online for a service group that is configured as a Global Group, in two clusters (Cluster1 and Cluster2) on which the group can come accross (each cluster only has a single server), it is taking a longer time to the service group to come online under a failover event. I am simulating a failover event on the server that is running the service group turning off it, to simulate a power supply cut off on that station! Please is there a parameter that I could modify to reduce this time? Attached you will find the service group relationship and its properties! Thank you Marlon1.6KViews1like5CommentsHow does mirroring work within Storage Foundation
How does storage foundation mirroring works (technical deep dive)? How does it sync, Synchronous or asynchronous? In other words, I have a LUN in Datacentre 1 mirrored with a LUN in Datacentre 2. Datacentre 2 is 50KM away from Datacentre 1. (Just an example) Will this slow down the system performance?Solved1.5KViews1like3Comments