07-24-2013 02:52 AM
Hi ,
I am getting one error as below:
Unable to connect to EMM database
error no:-77
07-24-2013 03:53 AM
more details please..
what is OS and Netbackup Version?
does it new installation or working one?
did you check the NBDB status?
/usr/openv/db/bin/nbdb_ping
show us the server.log.
/usr/openv/db/log/server.log
07-24-2013 05:55 AM
07-24-2013 08:28 AM
How much free space do you have where NBU is installed at ?
On the master server :
Check : HKEY_LOCAL_MACHINE\SOFTWARE\Veritas\NetBackup\CurrentVersion\Config
- double click on server and confirm the master server is listed first and all other servers listed exist.
- Confirm the client, browser and EMM_SERVER key are the master server.
If this is unix, confrim the bp.conf is correct.
Confrim the host and services file is correct.
Are all services running ? Espically nbemm and dbsrv ?
10-31-2013 11:01 AM
HI
I have installed netbackup 7.5 on windows7 64bit,
While i am trying to open activity monitor Unable to connect to the EMM server error(77).
thanks
Naidu
10-31-2013 11:45 AM
Do you have the GUI running directly on the Master server or is it on a remote Windows system with the admin console installed but logged into the Master?
10-31-2013 12:18 PM
Please post output of all of these commands from cmd:
hostname
ipconfig /all
bpclntcmd -self
(command is in <install-path>\veritas\netbackup\bin)
nbemmcmd -listhosts -verbose
nbemmcmd -getemmserver
(command is in <install-path>\veritas\netbackup\bin\admincmd)
See this post for similar issue:
https://www-secure.symantec.com/connect/forums/nbu7506-nbemmcmd-hangs#comment-9341851
10-31-2013 10:53 PM
try this
10-31-2013 10:56 PM
also share the output of following
nbemmcmd -listhosts
nbemmcmd -listsettings
C:\Program Files\Veritas\NetBackup\bin>bpps /s
11-01-2013 01:45 PM
I have moved the new question that was added to an old, unsolved post to a new discussion: https://www-secure.symantec.com/connect/forums/unable-connect-emm-server-error77