vxlicrep ERROR V-21-3-1015 Failed to prepare report for key
Dear all, we got a INFOSCALE FOUNDATION LNX 1 CORE ONPREMISE STANDARD PERPETUAL LICENSE CORPORATE. I have installed key using the vxlicinst -k <key> command. But when I want to check it using vxlicrep I'm getting this error for the given key: vxlicrep ERROR V-21-3-1015 Failed to prepare report for key = <key> We have Veritas Volume Manager 5.1 (VRTSvxvm-5.1.100.000-SP1_RHEL5 and VRTSvlic-3.02.51.010-0) running on RHEL 5.7 on 64 bits. I've read that the next step is to run vxkeyless set NONE, but I'm afraid to run this until I cannot see the license reported correctly by vxlicrep. What can I do to fix it? Thank you in advance. Kind regards, Laszlo4.2KViews0likes7CommentsVRTS STORAGE FOUNDATION ENTERPRISE HA 5.0 SOL
Hi Everyone, Can anyone please help me in understanding how does this product work and how is it licensed? Any document/link/licensing guide for the same will be of great help. Correct me if i am wrong, this is now Infoscale? I dont want to get in touch with a reseller before i have done my part of the R&D for the product and its licensing. Thanks in advance!Solved1.2KViews0likes3Comments- 1.2KViews0likes7Comments
Storage Foundation with VCS migration
Dear Experts, We have SFHA CFS with VCS 5.0 running on 2xHP Rx6600 Itanium Server with Oracle DB cluster. We are using VVR to replicate Oralce prod DB to replicate to DR site. All these version as of now are 5.0. We want to migrate to new Rx2800 i2 Itanium servers and want to use existing license. I checked and the tier of both servers model is same. My question are: 1. Can we install SFHA 5.1 SP1 on new Rx2800 i2 Server with same license keys? 2. The old server are running HPUX 11i v2 where as new will be HPUX 11i v3, will this have any issue is using old keys? 3. What are any other dependency/issue i should know in advance before we start this? Our team have misplaced all license docs and i can just find the license keys in current running server. I know it sounds stupid but we dont have SFHA 5.0 media and some how got a media with SFHA 5.1 SP1, so just thought of taking help in know what can be done and what cant. Thanks a lot for your efforts in advance..!!Solved999Views1like4CommentsStorage Foundation License Tiering
I'm going through some old license purchases, and i've come across a substantial number of Storage Foundation Standard licenses of various license tiers. It also looks like some of the purchases were made on one tiering system (1A, 4C etc), and others were made on a different system (A-N) Does anyone have any guidance on how I interpret these tiers to confirm what my license entitlement is? ThanksSolved2.1KViews1like7CommentsContact to get again Veritas software - version 5.0 MP4
Hello, In 2012 due to site accessing problem we have downloaded the Veritas software with temporary S/N provided by Symantec. Now we need to download again for a server re-instalaltion. Could you help where or how can we contact to get the software again? At this moment we have from archived data below information: - E-mail from Symantect with temporary S/N - Product key - SO number p.s. We have contacted our Logisitcs channel but it is taking time due to New Year holiday. Thanks with regards, Truong.655Views1like2CommentsLicensing for point in time copy on Oracle RAC
In my organization we have Oracle RAC running on RedHat Enterprise Linux and need to create a policy of data protection with continuous data protection. It is possible to do using only the Storage Foundation Enterprise for Linux or need additional products? What is the difference of Storage Foundation Enterprise for Linux and Storage Foundation for Oracle RAC and Veritas Storage Foundation High Availability?Solved985Views1like3CommentsHow to Downgrade SFHA Enterprise Edition to Standard Edition?
I have a requirement do downgrade a cluster from enterprise edition to standard edition. I have valid keys for both. I have removed the enterprise key and installed the standard edition key. Is there a list of other steps I must perform? I dont want any nasty supprised whenI reboot! Thanks.Solved883Views0likes1CommentVeritas Volume Manager 4_DG restoration
Hi I have a node which is SUN E2900 where SUN storage 6130 is connected.Veritas volume manager was configured in that node.Server's internal hard diskswere under VXVM.Apart from that other DG were created by using the storage disk.Now thing is that the server got completely crashed & I need to reconfigure the same from scratch.Please note that I have the explorer out put of the server.Now my question is that can I able to import the Dgs from the storage.Kindly suggest on this. Thanks in advance. regards...Arup881Views0likes8Comments