how to configure nbu appliance catalog backup
Hi, 1. I would like to knowhow to configure nbu appliance catalog backup. specify path for keep catalog? 2. and incase of catalog backup between site? HQ > master server is windows and branch master server is nbu appliance. how to configuration? (if not use AIR) thank you in advance.Solved3.8KViews0likes6CommentsNetbackup Appliance Slow Rehydration to tape and bad backup performance
Help! Netbackup Appliances 5230 2.6.0.2. One of our appliances houses ms-standard windows all local drives backups and vmware snapshot backups. Backups run at good speeds however as soon as we start our slps to copy the data from the msdp to tape the backups get extremely slow to barely moving and the copy to tape is slow. As soon as we kill off the slps backup speed goes back up again. We have a case opened and backline engineers have taken a look and we were told that is expected as the rehydration process tapeouts is slowing things down. We turned our max concurrent write drives to 4 and set our slp schedule to daytime to not affect nighttime backups however with these settings we will never get the month-end to tape done. We thought of a couple other options 1. backup to advanced disk then slp to msdp and or tape-issue here is we would need to buy more trays but even more important I think we would lose some features in Netbackup. last I checked netbackup accelerator doesnt work to advanced disk(I need to double-check) 2. inline tape copies-during month-end use inline tape copies to backup to msdp and tape, issue is speed will be run as the slowest backup between the two but that might be okay if the speed is good. Does anyone have any suggestions on this and been through this? Thanks.Solved2.8KViews0likes13CommentsStatus 2060019 and status 87 Killing same job
Got following errors in our details on a solaris backup. Im on an appliance, 5220. We are running 7.6.1.1. Link to 2060019 in error message is a cyclical redirect. I saw in other posts that this was a problem in the pre 7.5.0.4 world, but was supposed to be fixed in 7.5.0.5. Which is not our experience. Is there are work around for this? Anyone else seen it in the post 7.6.1.1 version? ​05/10/2015 00:56:17 - Critical bptm (pid=4960) Storage Server Error: (Storage server: PureDisk:servername) mtstrm_close_write_channel: Fatal error occured in Multi-Threaded Agent: Close Write Channel command failed: Cr_ErrnoException: Timed out after waiting 180s for the read threads to complete (cnt=1) V-454-96 05/10/2015 00:56:17 - Critical bptm (pid=4960) sts_close_handle failed: 2060019 error occurred on network socket 05/10/2015 00:56:17 - Critical bptm (pid=4960) sts_close_handle failed: 2060019 error occurred on network socket 05/10/2015 00:56:17 - Error bptm (pid=4960) cannot write image to disk, media close failed with status 2060019 05/10/2015 00:56:17 - Info bptm (pid=4960) EXITING with status 87 <---------- Thanks in advance.2.8KViews0likes4CommentsRe-Image Netbackup Appliance 5230
Hi All , I have Netbackup Appliance 5230 , i need to recover it by using USB but the original usb that came with the appliance is missing also the raid of server has been rebuild so there is no image currently running on . could you please Mention me the URL for origanal Image not Fixes or patchsrealse . Thanks ,Solved2.4KViews0likes3CommentsNew N5230 v2.6.1.1 master/media auto creates an extra backup policy.
When configuring a new N5230 as a master/media in v2.6.1.1, the process auto-created a standard backup policy which has the following as "Backup selections" within this auto-created backup policy: /msdp/cat/databases/catalogshadow /msdp/cat/databases/datacheck /msdp/cat/databases/spa /msdp/data/dp1/pdvol/etc /msdp/data/dp1/pdvol/var /usr/openv/lib/ost-plugins/pd.conf /usr/openv/lib/ost-plugins/mtstrm.conf However, the appliance has also auto-configured itself with an exclude list of: # cat /usr/openv/netbackup/exclude_list /advanceddisk /cat /msdp/data/ /msdp/cat/ /config . So, this new auto-created standard backup policywill ignore the first five selections of the backup policy that it created. Needless to say, I'm confused. Can anyone explain: 1) Whether this is correct? And why? ...or: 2) Whether this is incorrect? And why?Solved2.1KViews0likes13CommentsAppliance 5230 problem with Vm conversion vmware
Hi, i have a problem for restore a physical server with vm conversion. in my case my appliance is a master/media i have copied the vmtools iso into the /tmp to the appliance The gui ask me to choose the vmtools vmware when i brows my appliance, i can choose the iso, but when i run the pre-check, i was failed. i think, it's not the good method, but i don't find any docuements about vm conversion with appliance. Have you got any idea ? Thank's for your helpSolved1.7KViews0likes16CommentsHow to configure flashbackup-windows policy
How to configure flashbackup-windows policy ? Master/Media : NBU Appliance version 2.7.1 NBU Client Agent : 7.7.1 Policy Type : FlashBackup-Windows Backup Selection : \\. D:\ after I configure this and click OK but have error :Snapshot could not be create with auto method." Error code 71: None of the files mentioned inthe file list exist or may not be accessible. Best Regards, damrongpol.s1.5KViews0likes4Comments