How to write udev rules for persistent device name for DMP subpaths?
Hi experts, I'm using SFRAC 6.0.3 on Oracle Linux 5.8 with Oracle storage (2 HBA cards, 4 paths) and would like to make the DMP subpaths persistent after rebooting. I knew that for single path I can write the following udev rule: KERNEL=="sd*", BUS=="scsi", PROGRAM=="/sbin/scsi_id -g -u -s %p", RESULT=="<scsi_id>", SYMLINK+="<your_disk_name>%n" But it didn't work for multipath... Anyone can help on this issue? Thanks in advance... Thanks and Regards, Kiluwavxddladm show DMP state as not active
Goodmorning, I have issue that I can't seem to solve and I'm dire need of assistance. I have veritas cluster 5.1 running on solaris 10 connected to an 6180 storage array. The array is directly connected to 2 hotsts. (no switch!). Controller port 1A is connected to host A controller port 1B is connected to host A controller port 2A is connected to host B controller port 2B is connected to host B. DMP is taking care of the multipathing bit and looks ok, however I see that the state is set to not active: Output fromt the vxddladm listsupport libname=libvxlsiall.so : LIB_NAME ASL_VERSION Min. VXVM version ========================================================== Libvxlsiall.so vm-5.1.100-rev-1 5.1 The output of the vxdmpadm list dmpEngenio : Filename: dmpEngenio APM name: dmpEngenio APM version: 1 Feature : VxVM VxVM version 51 Array Types Supporred: A/PF-LSI Depending Array Types A/P State : Not-Ative Output from vxdctl mode: mode : enabled. Both hosts show the same result state : Not-Active So my question is : How do I set the state to Active. Bare in mind that this is a full production system so I have make sure that any commands given will not disrupt production. I will schedule downtime in that case. Can someone assist me? Many thanks! RemcoDMP, MPIO, MSDSM, SCSI-3 and ALUA configuration settings
Ok, I'm somewhat confused and the more I read the more confused I think I'm getting. I'm going to be setting up a 4 node active/active cluster for SQL. All of the nodes will have 2 seperate fiber channel HBAs connecting through 2 seperate switches to our NetApp. The NetApp supports ALUA, so the storage guy wants to use it. It is my understanding that I need to use SCSI-3 to get this to work. Sounds good to me so far. My question is, do I need to use any of Microsoft's MPIO or MSDSM? This is on Win 2008 R2. Or does Veritas take care of all of that? Also, I read that in a new cluster set up, only connect 1 path first and then install and then connect the 2nd path and let Veritas detect it and configure it. Is that accurate? Any info or directions you can point me will be greatly appreciated. Thanks!SolvedServer 2003 Spanned Dynamic disk (resize)
Under Server 2003 Disk Management, "extend volume" and "shrink volume" are greyed out. There are 4 SATA drives that create 2 partitions... 12GB and 211GB The 12 GB partition holds the OS, but requires more space. If I UN-Span these volumes, will I compromise data? All I want to do is expand the C: drive to hold all the MS updates. thanx for your timeSolvedformat display The current rpm value 0 is invalid, adjusting it to 3600 using dmp with EMC CX-4 in Solaris 10
I am currently working in a project using VxVM. The dmp is enabled for Mutlipath. However, when I type 'format' in command prompt. Searching for disks... The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 The current rpm value 0 is invalid, adjusting it to 3600 done c2t5006016141E0CABEd0: configured with capacity of 99.98GB c2t5006016841E0CABEd1: configured with capacity of 99.98GB c2t5006016841E0CABEd2: configured with capacity of 99.98GB c2t5006016141E0CABEd3: configured with capacity of 99.98GB c2t5006016841E0CABEd4: configured with capacity of 99.98GB c2t5006016141E0CABEd5: configured with capacity of 99.98GB c2t5006016841E0CABEd6: configured with capacity of 99.98GB c2t5006016141E0CABEd7: configured with capacity of 99.98GB c2t5006016841E0CABEd8: configured with capacity of 99.98GB c2t5006016141E0CABEd9: configured with capacity of 99.98GB c2t5006016841E0CABEd10: configured with capacity of 99.98GB c2t5006016141E0CABEd11: configured with capacity of 99.98GB c2t5006016841E0CABEd12: configured with capacity of 99.98GB c2t5006016141E0CABEd13: configured with capacity of 99.98GB c2t5006016841E0CABEd14: configured with capacity of 99.98GB c2t5006016141E0CABEd15: configured with capacity of 99.98GB c2t5006016144601064d0: configured with capacity of 99.98GB c2t5006016844601064d1: configured with capacity of 99.98GB c2t5006016144601064d2: configured with capacity of 99.98GB c4t5006016041E0CABEd0: configured with capacity of 99.98GB c4t5006016941E0CABEd1: configured with capacity of 99.98GB c4t5006016941E0CABEd2: configured with capacity of 99.98GB c4t5006016041E0CABEd3: configured with capacity of 99.98GB c4t5006016941E0CABEd4: configured with capacity of 99.98GB c4t5006016041E0CABEd5: configured with capacity of 99.98GB c4t5006016941E0CABEd6: configured with capacity of 99.98GB c4t5006016041E0CABEd7: configured with capacity of 99.98GB c4t5006016941E0CABEd8: configured with capacity of 99.98GB c4t5006016041E0CABEd9: configured with capacity of 99.98GB c4t5006016941E0CABEd10: configured with capacity of 99.98GB c4t5006016041E0CABEd11: configured with capacity of 99.98GB c4t5006016941E0CABEd12: configured with capacity of 99.98GB c4t5006016041E0CABEd13: configured with capacity of 99.98GB c4t5006016941E0CABEd14: configured with capacity of 99.98GB c4t5006016041E0CABEd15: configured with capacity of 99.98GB c4t5006016044601064d0: configured with capacity of 99.98GB c4t5006016944601064d1: configured with capacity of 99.98GB c4t5006016044601064d2: configured with capacity of 99.98GB AVAILABLE DISK SELECTIONS: 0. c0t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /pci@0,600000/pci@0/scsi@1/sd@0,0 1. c0t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /pci@0,600000/pci@0/scsi@1/sd@1,0 2. c1t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /pci@10,600000/pci@0/scsi@1/sd@0,0 3. c1t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /pci@10,600000/pci@0/scsi@1/sd@1,0 4. c2t5006016141E0CABEd0 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,0 5. c2t5006016841E0CABEd0 <DGC-VRAID-0326 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,0 6. c2t5006016841E0CABEd1 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,1 7. c2t5006016141E0CABEd1 <DGC-VRAID-0326 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,1 8. c2t5006016141E0CABEd2 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,2 9. c2t5006016841E0CABEd2 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,2 10. c2t5006016141E0CABEd3 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,3 11. c2t5006016841E0CABEd3 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,3 12. c2t5006016141E0CABEd4 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,4 13. c2t5006016841E0CABEd4 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,4 14. c2t5006016841E0CABEd5 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,5 15. c2t5006016141E0CABEd5 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,5 16. c2t5006016841E0CABEd6 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,6 17. c2t5006016141E0CABEd6 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,6 18. c2t5006016841E0CABEd7 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,7 19. c2t5006016141E0CABEd7 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,7 20. c2t5006016841E0CABEd8 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,8 21. c2t5006016141E0CABEd8 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,8 22. c2t5006016841E0CABEd9 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,9 23. c2t5006016141E0CABEd9 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,9 24. c2t5006016841E0CABEd10 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,a 25. c2t5006016141E0CABEd10 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,a 26. c2t5006016841E0CABEd11 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,b 27. c2t5006016141E0CABEd11 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,b 28. c2t5006016141E0CABEd12 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,c 29. c2t5006016841E0CABEd12 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,c 30. c2t5006016841E0CABEd13 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,d 31. c2t5006016141E0CABEd13 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,d 32. c2t5006016141E0CABEd14 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,e 33. c2t5006016841E0CABEd14 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,e 34. c2t5006016841E0CABEd15 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,f 35. c2t5006016141E0CABEd15 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,f 36. c2t5006016144601064d0 <DGC-VRAID-0428 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016144601064,0 37. c2t5006016844601064d0 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016844601064,0 38. c2t5006016144601064d1 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016144601064,1 39. c2t5006016844601064d1 <DGC-VRAID-0428 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016844601064,1 40. c2t5006016844601064d2 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016844601064,2 41. c2t5006016144601064d2 <DGC-VRAID-0428 cyl 13052 alt 2 hd 255 sec 63> /pci@1,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016144601064,2 42. c4t5006016041E0CABEd0 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,0 43. c4t5006016941E0CABEd0 <DGC-VRAID-0326 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,0 44. c4t5006016941E0CABEd1 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,1 45. c4t5006016041E0CABEd1 <DGC-VRAID-0326 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,1 46. c4t5006016941E0CABEd2 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,2 47. c4t5006016041E0CABEd2 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,2 48. c4t5006016041E0CABEd3 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,3 49. c4t5006016941E0CABEd3 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,3 50. c4t5006016041E0CABEd4 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,4 51. c4t5006016941E0CABEd4 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,4 52. c4t5006016041E0CABEd5 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,5 53. c4t5006016941E0CABEd5 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,5 54. c4t5006016041E0CABEd6 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,6 55. c4t5006016941E0CABEd6 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,6 56. c4t5006016041E0CABEd7 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,7 57. c4t5006016941E0CABEd7 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,7 58. c4t5006016041E0CABEd8 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,8 59. c4t5006016941E0CABEd8 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,8 60. c4t5006016041E0CABEd9 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,9 61. c4t5006016941E0CABEd9 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,9 62. c4t5006016041E0CABEd10 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,a 63. c4t5006016941E0CABEd10 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,a 64. c4t5006016041E0CABEd11 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,b 65. c4t5006016941E0CABEd11 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,b 66. c4t5006016041E0CABEd12 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,c 67. c4t5006016941E0CABEd12 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,c 68. c4t5006016041E0CABEd13 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,d 69. c4t5006016941E0CABEd13 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,d 70. c4t5006016041E0CABEd14 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,e 71. c4t5006016941E0CABEd14 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,e 72. c4t5006016941E0CABEd15 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016941e0cabe,f 73. c4t5006016041E0CABEd15 <DGC-VRAID-0326 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016041e0cabe,f 74. c4t5006016944601064d0 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016944601064,0 75. c4t5006016044601064d0 <DGC-VRAID-0428 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016044601064,0 76. c4t5006016044601064d1 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016044601064,1 77. c4t5006016944601064d1 <DGC-VRAID-0428 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016944601064,1 78. c4t5006016944601064d2 <DGC-VRAID-0428 cyl 51198 alt 2 hd 256 sec 16> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016944601064,2 79. c4t5006016044601064d2 <DGC-VRAID-0428 cyl 13052 alt 2 hd 255 sec 63> /pci@11,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016044601064,2 80. c8t0d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /pci@34,600000/pci@0/scsi@1/sd@0,0 81. c8t1d0 <SUN146G cyl 14087 alt 2 hd 24 sec 848> /pci@34,600000/pci@0/scsi@1/sd@1,0 82. c10t5006016841E0CABEd0 <drive type unknown> /pci@35,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016841e0cabe,0 83. c10t5006016141E0CABEd0 <drive type unknown> /pci@35,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016141e0cabe,0 84. c10t5006016144601064d0 <drive type unknown> /pci@35,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016144601064,0 85. c10t5006016844601064d0 <drive type unknown> /pci@35,700000/SUNW,qlc@0/fp@0,0/ssd@w5006016844601064,0 How can I solve this problem? the host is not a cluster host. Thank you for advanced. Johnston chanHow Can I Disable DMP?
I have a customer who installed HDLM along with Storage Foundation 5 on a Solaris 10 server. Not surprisingly, they had issues. Now they want to keep HDLM and Volume Manager but disable DMP. While I do not agree with this approach, I've been given the task to disable DMP. So, I know I can use vxdmpadm exclude vxdmp to exclude controllers from being considered by DMP. My question is, is there a way to completely disable DMP altogether, or is excluding disks the best way to go? I've found references on the Symantec support site that discuss disabling DMP for earlier versions of Storage Foundation but nothing that relates to SF 5.Solved