Forum Discussion
MitchR
17 years agoLevel 6
Update: After talking to Symantec support for over an hour (re-apply this patch, reinstall drivers, reboot, repeat, repeat....) with no luck, I found the cause.
While the library was powered on and working, my ML6000 was set to off-line. Apparently this setting survives a reboot on the library itself. (joy) A vauge memory tells me we had this same problem last time we did a firware update.
Now we're having problems using any tape slot over 100, reporting:
The job failed with the following error: Library error - invalid element address.
After reading the "How to troubleshoot library issues" document, I'm trying to downgrade the library firmware to see if that helps.
Related Content
- 10 months ago
- 8 years ago