error ( Cannot Connect On Socket )
Hey Everybody, I was working on a Issue, The error ( Cannot Connect On Socket ) occurs while trying communicate a Client from Master server. Checked BPCD logs and test the connectivity b/w client and master, which is not happening. Found that "Windows Firewall" service is running on the server. Now by disabling the Firewal this issue could get resolved. But my concern is ( as Firewall is used to protect the server from virus or any harmful objects ). Why we have to Disable it ? Why NBU connection failed when server is Behind firewll ? Why can not we take backup along with Firewall Enabled ?Solved28KViews1like12Commentschange the logon account service using command line netbackup
Hello all, innetbackup i want to change the logon account service using command line allthough i alreadyknow how to change the services manually but it is not helpful for my testing purpose. Manual procedure is mention below" To configure the log on account for the NetBackup Client Services Any one help me.......any kind of help is appreciated... Thanks Open the Windows Services application. Double-click on the NetBackup Client Service entry. Click on the Log On tab. If Local System account is not selected as the Log on as account, proceed with step 9. Provide the name of the user account that you created for the NetBackup Client Service. The account must include the domain name, followed by the user account, domain_name\account . For example, recovery\netbackup . Type the password. Click OK. Stop and start the NetBackup Client Service. Close the Services control panel application I want to done above mention procedure but using command.Solved23KViews0likes4CommentsERROR: Error 1335.The cabinet file 'Data1.cab' required for this installation is corrupt and cannot be used. This could indicate a network error, an error reading from the CD-ROM, or a problem with this package.
Hi all, through installation of netbackup softwareI got this message : ERROR: Error 1335.The cabinet file 'Data1.cab' required for this installation is corrupt and cannot be used. This could indicate a network error, an error reading from the CD-ROM, or a problem with this package. I believe it is windows issue.kindly provide me steps needs to follow forsolvin this issue. I tried to disable and enable windows moduler but no result. Regards,Solved22KViews1like12Commentsunable to log into Netbackup GUI (Status 526)
Hi all i'm having trobule with a box running redhat 5 and netbackup 7.1, i cant connect to the GUI, i get unbale to log in, status 526 From the log, i get the below - Connecting to vnetd service over PBX port = 1556 ServerInterface:Logon:Exception encountered null ServerInterface:Logon - Initial host:null, Current host:valorum, PBX port:1556 Can not connect to the NB-Java authentication service on valorum on port 1556. Exception: vrts.common.server.CantConnectToAuthServViaVNETDException Any ideas what can cause this? ThanksSolved22KViews3likes7CommentsExit Status: 48 (client hostname could not be found)
Hi all, I have an environment consist of cluster master server windows 2008and 5 media servers and 2 5020 appliances.I installed agent on the linux redhat client and and i added all server list to bp.conf and etc/hosts in the client and i added the client name in the master server host file.when i'm trying to ping from the client every thing working fine,but i couldnot do this from the master to client.then when i configured the policy the jobs failed with status Exit Status: 48 (client hostname could not be found) then I ran command bptestbpcd -client from master with -debug i got this result: C:\Program Files\Veritas\NetBackup\bin\admincmd>bptestbpcd -client BEC13-ENC2-2 -debug 16:09:32.930 [3444.5668] <2> bptestbpcd: VERBOSE = 0 16:09:32.946 [3444.5668] <2> copy_preferred_network_list: ../../libvlibs/nbconf. c.1610: pseudo PN for : bec12-encx-v37 16:09:32.946 [3444.5668] <2> copy_preferred_network_list: ../../libvlibs/nbconf. c.1610: pseudo PN for : bec12-encx-v37 16:09:32.961 [3444.5668] <2> copy_preferred_network_list: ../../libvlibs/nbconf. c.1610: pseudo PN for : bec12-encx-v37 16:10:02.963 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:10:14.964 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:10:14.964 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:10:45.965 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:10:57.966 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:10:57.966 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:11:08.982 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:11:38.984 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:11:53.984 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:11:57.985 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:12:05.001 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:12:35.002 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:12:43.002 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:12:46.003 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:13:07.004 [3444.5668] <8> async_connect: [vnet_connect.c:1653] getsockopt SO_ ERROR returned 10060 0x274c 16:13:07.004 [3444.5668] <16> connect_to_service: connect failed STATUS (18) CON NECT_FAILED status: FAILED, (42) CONNECT_REFUSED; system: (10060) Connection timed o ut.; FROM 172.20.124.11 TO BEC13-ENC2-2 172.20.165.4 bpcd VIA pbx status: FAILED, (42) CONNECT_REFUSED; system: (10060) Connection timed o ut.; FROM 172.20.124.11 TO BEC13-ENC2-2 172.20.165.4 bpcd VIA vnetd status: FAILED, (42) CONNECT_REFUSED; system: (10060) Connection timed o ut.; FROM 172.20.124.11 TO BEC13-ENC2-2 172.20.165.4 bpcd 16:13:07.004 [3444.5668] <8> vnet_connect_to_bpcd: [vnet_connect.c:279] connect_ to_service() failed 18 0x12 16:13:07.004 [3444.5668] <2> local_bpcr_connect: Can't connect to client BEC13-E NC2-2 16:13:07.004 [3444.5668] <2> ConnectToBPCD: bpcd_connect_and_verify(BEC13-ENC2-2 , BEC13-ENC2-2) failed: 25 <16>bptestbpcd main: Function ConnectToBPCD(BEC13-ENC2-2) failed: 25 16:13:07.004 [3444.5668] <16> bptestbpcd main: Function ConnectToBPCD(BEC13-ENC2 -2) failed: 25 <2>bptestbpcd: cannot connect on socket 16:13:07.004 [3444.5668] <2> bptestbpcd: cannot connect on socket <2>bptestbpcd: EXIT status = 25 16:13:07.004 [3444.5668] <2> bptestbpcd: EXIT status = 25 cannot connect on socket C:\Program Files\Veritas\NetBackup\bin\admincmd> please advice what is missed??? Regards,Solved20KViews1like16CommentsDifference between Differential Inc backup and Cumulative Inc backup.
All my backups are archive bit dependant. Please let me know what is the difference we are backing up in Differential Inc backup and Cumulative Inc backup, if below definitions are correct. Please find the attachement. Thanks and regards, Bharath AcharSolved19KViews1like5CommentsFailed to load media management library. Additional Information : 2
Hi All, I am getting below error with RMAN. Client : AIX Netbackup : NetBackup-AIX53 7.1 Master server : SunOS 5.10 Generic_147440-01 sun4u sparc SUNW Netbackup master server : NetBackup-Solaris10 7.1.0.3 RMAN-00571: =========================================================== RMAN-00569: =============== ERROR MESSAGE STACK FOLLOWS =============== RMAN-00571: =========================================================== RMAN-03002: failure of backup command at 10/20/2014 07:25:11 ORA-19554: error allocating device, device type: SBT_TAPE, device name: ORA-27211: Failed to load Media Management Library Additional information: 2 RMAN> Recovery Manager complete. Steps taken so far: 1. We have tried to relink the library. 2. Shutdown the DB and brought it online, relinked again. 3. Client machine was rebooted 80 days back. Please let me know how to proceed further.. Note: The machine (client) acts as a media server as well.Solved19KViews6likes7CommentsError code 21-Socket open failed in NetBackup
Hi All, I was facing error code 21- Scoket open failed issue from long back. While trouble shooting, I have restarted NetBackup Client Service. Still am facing same issue. Can any one suggest on this and provide solution for this to fix it. OS: Windows NetBackup version: 6.5 Thanks in Advance, Sam.Solved18KViews1like8Commentsbphdb exit status = 6: the backup failed to back up the requested files
Hello, we are getting error on Below RMAN Backup.. please suggest what is the issue with it and what can be done to resolve it..Thanks Master Serve is Windows 2008, Netbackup 7.5 client is Windows Windows 2003 Oracle 10G R1 below is Netbackup error.. 06/08/2014 16:55:46 - connecting 06/08/2014 16:55:49 - Info bpbrm (pid=13560) starting bphdb on client 06/08/2014 16:55:49 - connected; connect time: 0:00:00 06/08/2014 16:55:52 - Info bphdb (pid=5448) Backup started 06/08/2014 16:55:54 - Error bpbrm (pid=13560) from client tmgsdhypprddb: ERR - Script <"C:\Program Files\Veritas\NetBackup\scripts\hot_database_backup_hypp.cmd"> failed with status: <1> 06/08/2014 16:55:56 - Error bpbrm (pid=13560) from client tmgsdhypprddb: ERR - Script <"C:\Program Files\Veritas\NetBackup\scripts\hot_database_backup_hypdb.cmd"> failed with status: <1> 06/08/2014 16:55:56 - Error bpbrm (pid=13560) from client tmgsdhypprddb: ERR - bphdb exit status = 6: the backup failed to back up the requested files 06/08/2014 16:55:59 - Info bphdb (pid=5448) done. status: 6: the backup failed to back up the requested files 06/08/2014 16:55:59 - end writing the backup failed to back up the requested files (6)Solved18KViews1like8Comments