10-30-2008 03:45 AM
Hi to all,
i have recently added 2 new cleaning tapes to my robot entry/exit slots, and in my netbackup 6.5 i made "inventory robot" choosing the options "update volume configuration" and "empty media access port prior to update". The cleaning tapes were added ok but were placed in "netbackup" volume pool and the media type was identified as HCART3, meaning that he is detecting the tapes as regular tapes and not cleaning tapes.
the bar code is CLN***** and netbackup has no problem reading it. What can be causing this? Should i delete this tapes and add them manually with the "new volume" option?
thanks in advance
10-30-2008 04:03 AM
Have you tried barcode rules?
We have one set up for our cleaning tapes:
Barcode Tag: CLN
Cleanings: 25
Media Type: 1/2" cleaning tape 3
Volume Pool: none
Description: Cleaning Tape
Our cleaning tapes are then placed in the 'None' pool with a media type of HC3_CLN.
10-30-2008 04:10 AM
Check that your barcodes are "cleaning tape barcodes".
Barcodes for universal cleaning tapes should end with CU, LTO3 cleaning tapes with C3 etc.
Edit: example CLNU001CU