08-02-2012 07:06 AM
I have tried all tech articles I could find on knowledge base and I still have no clue how to do it.
I am close to go with manual inventory. (2 min on every tape)
Any hint will be helpful.
TIA
08-02-2012 07:09 AM
Refer to http://www.symantec.com/docs/TECH68896
08-02-2012 07:18 AM
Thank you for trying but I have 12 version and this tech works only for 12.x :(
I am currently instaling 12.5 trial and will try migrate first to 12.5 version.
Any other ideas ? :)
08-02-2012 07:22 AM
Catalog file format is same for all versions of BE from 11d onwards.
To be on a safer side, rename existing catalogs folder and create a new catalogs folder in the
installation directory of BE2012. Copy catalogs from BE12 to BE2012 and than restart all the services.
08-02-2012 07:33 AM
I have tried this but I have new version on new server (diffrent server names).
I even tried to index that files but new BE (2012) didn't recognise it.
And my trial 12.5 version file is broken so I am lost.
08-02-2012 07:35 AM
Different server name shouldn't affect the migration of catalogs.
08-02-2012 08:03 AM
08-02-2012 05:45 PM
There are a lot of changes in the storage area for BE 2012. The B2D folders are changed to Disk Storage or Legacy B2D folders. Just simply copying the catalogs from an older version to BE 2012 would probably not work because of these changes. It would be better to re-catalog your media in BE 2012. See my article below
https://www-secure.symantec.com/connect/articles/be-2012-restoring-data-defunct-server
The procedure is also applicable for tapes.