01-14-2010 10:34 AM
01-14-2010 06:34 PM
01-14-2010 06:55 PM
VCS don't use the monitor script but it use MonitorProcess as in the picture
but the VCS engine log say that
#####
ps : invalid listing of the -u
#####'
I have tested in the AIX5.3 with SFHA5.0MP3, therer is no problem like this.
Thank you very much
01-14-2010 06:55 PM
VCS don't use the monitor script but it use MonitorProcess as in the picture
but the VCS engine log say that
#####
ps : invalid listing of the -u
#####'
I have tested in the AIX5.3 with SFHA5.0MP3, therer is no problem like this.
Thank you very much
01-14-2010 07:46 PM
01-14-2010 08:09 PM
Hello
It is a binary.
wac: executable (RISC System/6000) or object module not stripped.
It is a GCO process.
Thank you
01-14-2010 08:40 PM
01-14-2010 11:15 PM
01-15-2010 01:02 AM
01-15-2010 07:36 AM
01-15-2010 08:00 AM
01-18-2010 12:45 AM
01-18-2010 03:41 AM
01-19-2010 08:26 AM
Hi,
did a little research today. Like pgm10s mentioned above there is no problem in AIX 5.3 and SFHA5.0 MP3. And because I cannot beleave that AIX 6.1 has a change in ps command (at least not that significant) I suspect there is a bug in the monitor entry point in ApplicationAgent of SFHA5.1. Too bad... (Btw. the Agent for Solaris Sparc and for Solaris Intel is running as expected.)
But I promised a workaround...
Just make a new Script: /opt/VRTSvcs/bin/wacmonitor
eval 'exec ${VCS_HOME:=/opt/VRTSvcs}/bin/perl5 -S $0 ${1+"$@"}' if 0;$exit_code=100; open FH, "ps -eo pid,comm | grep /opt/VRTSvcs/bin/wac | grep -v grep |" or die "Failed to open pipeline"; while ($line=<FH>) { if ($line =~ /\/opt\/VRTSvcs\/bin\/wac/) { $exit_code=110; } } exit $exit_code;
And than use it in MonitorProgram attribute and delete the MonitorProcess attribute entry.
I am aware that after an update this setting is gone (probably). Should do the job as long as you have only one wac process running, if you have more than one wac running the monitor script is not correct because as long on process lives this script returns "online". In this case you have also test for some parameters (you can get those parameters from the ArgList atttribute in the type description.
Hope this helps
Roger