Discussion Posts

Resolved! Path Failed-over timne for SFW

Hello      - I implement the SAN LUNs under the VXVM control (DSM DMP)on MS Winodws 2012 using 2 paths for each LUNs. While I test copy the data, I unplug one FC ( one path), the copy progress is paused about 20 sec and then continue. I am not sur...

pgm10s by Level 5
Partner Accredited Certified
  • 1388 Views
  • 2 replies
  • 0 kudos

Resolved! Storage Foundation

Hi im new to the product and the field, so really any advice would be great. where exactly do you install VOM in your SAN environment and does the SF s/w collide with the storage vendor management s/w. And how do you control a heterogenous storage ...

Resolved! ForceImport

Hi all, I need help to good understand attribute ForceImport.   There is a table "Failure situations" in Symantec Storage Foundatio and High Availability Solutions Solutions Guide. (221p.) I don't understant situation number 7 Split-brain situati...

Resolved! Service Monitor

Hi, I have problem with serviceMonitor agent. I created script(www.bat): @echo off ping 172.16.11.1>nul if %errorlevel% == 0 goto A :A exit 110 if %errorlevel% == 1 goto B :B exit 100 Script's directory - C:\Program Files\Veritas\cluster s...

Windows generic service faults on its own

Hi, Ia have a two node failover cluster SFHA 6.1 running over Windows 2012R2. I want to monitorize a generic windows service.  The problem is that after a time the Generic service is faulted and switched to the node 2. The resource brings online i...

achebib by Level 4
Partner
  • 452 Views
  • 1 replies
  • 0 kudos

Resolved! how to check DMP in VCS is working?

Hi,   We installed Storage foundation HA 6.1 with DMP set with all option marked. Before that we had the EMC power-path application, where we could see that multipathing sees all disks from all available paths. now we have the SFHA DMP option ins...

Resolved! Storage Foundation 6 and Windows 2003 MS Clustering

Hi . I having some issue to failover my cluster node databases drive after i have performed a restoration of the entire systems OS due to hardware faulty. We able to failover those shared drives outside the SFW configuration .   Can anyone advise...

demo4119 by Level 6
Partner Accredited Certified
  • 1277 Views
  • 3 replies
  • 1 kudos

Windows File System mount issue

Hello, I have configured the FS in Windows Server, all the sudden it is not mounting.  I can imprt the VG, but volume is not getting mounted. What is the correct to log file to check the issue?

mokkan by Level 6
Certified
  • 686 Views
  • 5 replies
  • 0 kudos

Resolved! MS Cluster Storage migration problem

Hi guys, Could you please help me with storages migration problem. We have some WinServ 2003 clusters in our company and now we have a task to migrate our old SANs to the new ones. The best way we imagined as solution is to create 2 dynamic DG in V...

skia by Level 2
  • 2719 Views
  • 6 replies
  • 0 kudos

DG(mirror) went offline when 1 lun in DG failed.

Hello    I have configure Cluster DG with MS cluster. On the share DG, I configure mirror volume that come from 2 storages. So in DG we have 2 plexes , 2 Disk (LUN). When 1 of LUN failed (1 of storage failed), why the entire DG failed (offline)? ...

pgm10s by Level 5
Partner Accredited Certified
  • 461 Views
  • 3 replies
  • 1 kudos

The error occurs when hastart.

product : sfwha 5.1 os : windows 2003 enterprise issue : The active normal, but when the hastart in the standby to the error occurred.           hastart           VCS INFO V-16-1-11020 Starting HAD on local node           VCS ERROR V-16-11109 Ca...

Howto remove SFW CP21 patch

Environment Primary Site Node = SFW 5.1 SP2 Primary Site Node = SFW 5.1 SP2 CP21 I tried to install the CP21 patch on Primary node and while installation my service got hannged to to somw reason. I hard booted the node. Now when I run the command ...

Zahid_Haseeb by Moderator
Partner    VIP    Accredited
  • 359 Views
  • 1 replies