New Media Apears as Cleaning Media...

Dave_C
Level 4
Hi there... I'm running a Dell PE2650 With a 20 slot changer a PV132T Unit from Dell. on a W2003 Server, however I'm still using BE V9.1.

Everytime I insert new SDLT Media into any of the slots, after running a full inventory against the changer it reports that, the newly inserted media is cleaning media...I've tried four new tapes now...Anyone seen this before..?

Rgs
5 REPLIES 5

Deepali_Badave
Level 6
Employee
Hello,

As a preliminary step verify if the device is comaptibel with BE v9.1.

Please refer the following HCL:

http://seer.support.veritas.com/docs/282347.htm


Thank you & regards,

Dave_C
Level 4
Thanks I've already checked into this, I'm working on 40 + Dell PV132T Units, and they are listed as being compatible with BE V9.1

Deepali_Badave
Level 6
Employee
Hello,

Try disabling and deleting the device.

Please refet the following technote:

http://seer.support.veritas.com/docs/268626.htm

Thank you & regards,Message was edited by:
Deepali Badave

Adam_Gottstein
Level 3
On the few occassions I have had BE refuse to detect my tape as nothing but a cleaning media, though it wasn't, I found the following to work:

1) Delete the media in question from the "All Media" section
2) Stop all the BE services.
3) Stop the SQL Service for the Backup Exec database.
4) Start the SQL Service as well as the SQL Server Agent
5) Start the BE Services
6) Perform a quick erase on the media in question.

I've only had this problem a couple of times, but the above steps resolved the problem each time.

Shilpa_pawar_2
Level 6
Hi,

Please update us on the issue.

Also install latest drivers http://seer.support.veritas.com/docs/273853.htm and refer: http://support.veritas.com/docs/190522

regards,
Shilpa