bengine.exe failures.

Al_Wilson
Level 5
Hi,

Our jobs are failing, and are coming up as either 'recovered' or failed, and the current Job Status as either 'On Hold' or 'Server Paused'.

Following error in event log popped up 3 times overnight...

'Faulting application bengine.exe, version 10.1.5629.0, faulting module catcommon.dll, version 10.1.5629.0, fault address 0x00010033.'

Then this one after the others...

Faulting application beserver.exe, version 10.1.5629.0, faulting module unknown, version 0.0.0.0, fault address 0x00320031.

Is this just a case of replacing catcommon.dll? Are there any hotfixes needed?

Cheers,
Al.
1 REPLY 1

Shilpa_pawar_2
Level 6
Hi,

Try installing hotfix 19:
http://support.veritas.com/docs/282310