09-23-2010 05:13 PM
Hello,
I'm trying to restore a server from a Full backup Using BE 2010 with IDR. I've used the .DR file and applied the volumes from the backup, selected my B2D folder and proceeded to recover. At first I could see on the "Restoring Data" status screen that libraries were been initialized and used. So I let this run over night and this morning when I came in I just see an endless loop of "Initializing robotic library, please wait" and "Rewinding media". Any idea why it's doing this?
Regards,
Justin
09-23-2010 06:22 PM
1) Did you backup your data onto tapes or B2D folders?
2) Did you select automatic recovery?
09-23-2010 08:37 PM
I backed up to B2D folders on a USB Drive. I did use the automatic recovery.
09-23-2010 08:45 PM
During the restore process, is the USB drive attached to a media server or to the server that is to be restored?
I did successfully test an IDR restore with BE 2010, but my restore was from tape attached to a media server.
09-23-2010 09:48 PM
It's attached to the server that is been restored.