Hello J Barrett,
On multiple nic configuration, NIC Class GUID may be different from backup. This causes the integrity of network configuration to be destroyed.
Refer to MS article:Q318715.
Please reinstall tcp/ip, NIC driver, and AFT setting.
When a NIC teaming is configured, a "virtual NIC" (Network Interface Card) is created by the NIC teaming software. Network requests are then addressed to the virtual NIC, which then passes the requests to the physical NICs.
the virtual NIC must be configured with a MAC (Media Access Control) address that is different from the MAC addresses of the physical NICs.
To avoid this problem, the virtual NIC must be configured with a MAC address that is different from the MAC addresses of the physical NICs.
Additional Information :
For information on the recent VERITAS Backup Exec security vulnerabilities, including links to the downloads for the necessary hotfixes, please refer to the following document:
Patch summary for Security Advisories VX05-001, VX05-002, VX05-003, VX05-005, VX05-006, VX05-007
http://seer.support.veritas.com/docs/277429.htm
NOTE : If we do not receive your reply within two business days, this post would be marked assumed answeredand would be moved toanswered questions pool.