09-11-2014 02:28 AM
Hello and thanks to everyone,
All the Verify Jobs for Virtual Machine(Hyper-V based) fail with error V-79-57344-33991.
No problems for Verify Job of Physical machine.No problems with Backup Job or Restore Job.
All the backup data go to a deduplicated Iomega disk.
We have Backup Exec 2012 Version 14 Revision 1798
How could i try to solve the problem?
Solved! Go to Solution.
09-12-2014 12:27 AM
09-11-2014 03:13 AM
09-11-2014 03:17 AM
Sorry, I have deleted the other post
09-11-2014 03:44 AM
09-11-2014 04:55 AM
Verify- \\XXXX.AAAA.IT\System?State \\XXXX.AAAA.IT\System?StateAn unknown error occurred on device "Iomega - Deduplicated:1".
V-79-57344-33991 - A backup storage read/write error has occurred.
If the storage is tape based, this is usually caused by dirty read/write heads in the tape drive. Clean the tape drive, and then try the job again. If the problem persists, try a different tape. You may also need to check for problems with cables, termination, or other hardware issues.
If the storage is disk based, check that the storage subsystem is functioning properly. Review any system logs or vendor specific logs associated with the storage to help determine the source of the problem. You may also want to check any vendor specific documentation for troubleshooting recommendations.
09-11-2014 07:57 AM
This is the error found in the windows event log.
Event ID 33152
Adamm Mover Error: Read Failure!
Error = ERROR_CRC
Drive = "Iomega - Deduplicated:2"
{9992E2E1-E3AE-40AD-A85A-34DFA61837A0}
Media = "OST00001148-4ADE7440F19DD76F"
{1A389541-77BE-4C7A-B850-9665722B6255}
Read Mode: SingleBlock(0), ScsiPass(0)
Write Mode: SingleBlock(1), ScsiPass(1)
09-11-2014 08:41 AM
09-11-2014 08:50 AM
Yes it's a device with dedup capability it's an IOMEGA IX4 200D. We use this device with Backup Exec for almost 2 years without any kind of problems.Now it's since 15 days that comes this issue with verify job.
09-11-2014 09:00 AM
09-12-2014 12:03 AM
Ok,but why now Bakcup exec gives problems and only with virtual Machine?Physical Machine verify job no problems.
Could be any recent updates?
09-12-2014 12:27 AM