OK.. I've had the lovely frustrations of the RD1000 not ejecting since upgrading and think we now have that under control, so now I have to deal with my failing jobs... These jobs worked just fine under 11d, and now are failing with Final error: 0xe00084af - The directory or file was not found, or could not be accessed. This is my exchange database backup and therefore VERY important.
When I go to the referenced KB article,
http://seer.entsupport.symantec.com/docs/326836.htm
None of these conditions are true.
1. The resource does exist... it is my exchange database.
2. The username/password have not changed.
3. It's not on another server so we are not remotely accessing anything.
What I don't understand is why there isn't anything telling you if you were doing X in 11 you need to do Y in 12. I've never had so many problems with a BE upgrade.
Here's the section from the Job Log
Backup- \\EXCHANGE\Microsoft Information Store\First Storage Group
Database was not found, or could not be accessed.
Database was not found, or could not be accessed.
HELP! I'm pulling out my hair, and I don't have much left!
Thanks!