Getting error code 800

sagar666
Level 5

Hi Team,

Recently I have changed Tapes

1.LTO5 3TB (labled XXXXL1)

2. we are using IBM-ULT3580 drives

3. Dell tl4000 hardware box

After changing tapes I have reciving error code 800. below is the job details and some times drive itself going down. Wheather my tapes support IBM-ULT3580 drives?  

05/10/2015 11:09:26 - Info nbjm (pid=2244) starting backup job (jobid=5806) for client inbmaster, policy meteor_mnt_home, schedule Full
05/10/2015 11:09:26 - Info nbjm (pid=2244) requesting STANDARD_RESOURCE resources from RB for backup job (jobid=5806, request id:{EBAD8DC0-F6D6-11E4-B6F6-7F838A77269E})
05/10/2015 11:09:26 - requesting resource Any
05/10/2015 11:09:26 - requesting resource inbmaster.asicdesigners.com.NBU_CLIENT.MAXJOBS.inbmaster
05/10/2015 11:09:26 - requesting resource inbmaster.asicdesigners.com.NBU_POLICY.MAXJOBS.meteor_mnt_home
05/10/2015 11:09:26 - Error nbjm (pid=2244) NBU status: 800, EMM status: The robotic library is not defined in EMM
resource request failed  (800)

I have started one more jobs its hanged in same place. below is the job details

 

05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Suspending further messages if reset access time fails
05/11/2015 13:57:11 - Error bptm (pid=16038) error requesting media, TpErrno = Robot operation failed
05/11/2015 13:57:11 - Warning bptm (pid=16038) media id 0061L1 load operation reported an error
05/11/2015 13:57:11 - current media 0061L1 complete, requesting next media Any
05/11/2015 13:57:15 - Info bptm (pid=16038) Waiting for mount of media id 0061L1 (copy 1) on server inbmaster.asicdesigners.com.
05/11/2015 13:57:15 - granted resource  0061L1
05/11/2015 13:57:15 - granted resource  IBM.ULT3580-HH4.000
05/11/2015 13:57:15 - granted resource  inbmaster-hcart-robot-tld-0
05/11/2015 13:57:15 - mounting 0061L1

 

Thanks for help

1 ACCEPTED SOLUTION

Accepted Solutions

Nicolai
Moderator
Moderator
Partner    VIP   

You are trying to bypass a security feature.

If it works using LTO1 labels with LTO5 tape and drives, is down to the firmware in the robot. It may reject mounting "LTO1" (LTO1 labeld LTO5 media) tapes in a LTO5 drive because LTO1 not compatible with LTO5 drives.

Buying a new set of LTO5 labels does not cost much - Please consider this.

 

HCART, HCART2, HCART3 is not related to LTO revisions. It is just a marker e.g red tapes for red tape drives, yellow for yellow. HCART2 tapes for HCART2 tape drives

View solution in original post

10 REPLIES 10

Marianne
Level 6
Partner    VIP    Accredited Certified
Nothing to do with media: Here is the error: "EMM status: The robotic library is not defined in EMM resource request failed (800)" Something wrong with device config. Another error is with tape load of a LTO1 tape. What model tape drive is is in robot 0 on inbmaster? If LTO3 or higher, the drives cannot write to LTO1. Show us device config on inbmaster: tpconfig -l

sagar666
Level 5

Hi,

Tape model is

tpconfig -l

 ./tpconfig -l
Device Robot Drive       Robot                    Drive                Device     Second
Type     Num Index  Type DrNum Status  Comment    Name                 Path       Device Path
robot      0    -    TLD    -       -  -          -                    /dev/sg6
  drive    -    0  hcart    2    DOWN  -          IBM.ULT3580-HH4.000  /dev/nst1
  drive    -    1  hcart    1    DOWN  -          IBM.ULT3580-HH4.001  /dev/nst0


HP LTO-5 Ultrium RW

I labled at the end L1 is that a problem? It must be labled L5?

Below is another job error 252. after that other jobs are ended with error code 800

 

05/11/2015 13:41:36 - Info nbjm (pid=2244) starting backup job (jobid=5817) for client inbmaster, policy meteor_mnt_home, schedule Full
05/11/2015 13:41:36 - Info nbjm (pid=2244) requesting STANDARD_RESOURCE resources from RB for backup job (jobid=5817, request id:{583A7870-F7B5-11E4-BAD1-4BAB0311E526})
05/11/2015 13:41:36 - requesting resource Any
05/11/2015 13:41:36 - requesting resource inbmaster.asicdesigners.com.NBU_CLIENT.MAXJOBS.inbmaster
05/11/2015 13:41:36 - requesting resource inbmaster.asicdesigners.com.NBU_POLICY.MAXJOBS.meteor_mnt_home
05/11/2015 13:41:37 - Info bpbrm (pid=16033) inbmaster is the host to backup data from
05/11/2015 13:41:37 - Info bpbrm (pid=16033) reading file list from client
05/11/2015 13:41:37 - Info bpbrm (pid=16033) starting bpbkar on client
05/11/2015 13:41:37 - Info bpbkar (pid=16037) Backup started
05/11/2015 13:41:37 - Info bpbrm (pid=16033) bptm pid: 16038
05/11/2015 13:41:37 - Info bptm (pid=16038) start
05/11/2015 13:41:37 - Info bptm (pid=16038) using 65536 data buffer size
05/11/2015 13:41:37 - Info bptm (pid=16038) using 30 data buffers
05/11/2015 13:41:37 - Info bptm (pid=16038) start backup
05/11/2015 13:41:37 - Info bptm (pid=16038) Waiting for mount of media id 0061L1 (copy 1) on server inbmaster.asicdesigners.com.
05/11/2015 13:41:37 - granted resource  inbmaster.asicdesigners.com.NBU_CLIENT.MAXJOBS.inbmaster
05/11/2015 13:41:37 - granted resource  inbmaster.asicdesigners.com.NBU_POLICY.MAXJOBS.meteor_mnt_home
05/11/2015 13:41:37 - granted resource  0061L1
05/11/2015 13:41:37 - granted resource  IBM.ULT3580-HH4.001
05/11/2015 13:41:37 - granted resource  inbmaster-hcart-robot-tld-0
05/11/2015 13:41:37 - estimated 1221961036 kbytes needed
05/11/2015 13:41:37 - Info nbjm (pid=2244) started backup (backupid=inbmaster_1431331897) job for client inbmaster, policy meteor_mnt_home, schedule Full on storage unit inbmaster-hcart-robot-tld-0
05/11/2015 13:41:37 - started process bpbrm (pid=16033)
05/11/2015 13:41:37 - connecting
05/11/2015 13:41:37 - connected; connect time: 0:00:00
05/11/2015 13:41:37 - mounting 0061L1
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/MegaSAS.log. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/.DS_Store. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/._.DS_Store. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/IP_Addresses.txt. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/ajitb/.ICEauthority. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/ajitb/.Xauthority. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/ajitb/.alias. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/ajitb/.bash_history. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/ajitb/.bash_logout. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Could not reset access time of /mnt/star_home1/ajitb/.bash_profile. Errno = 30: Read-only file system
05/11/2015 13:41:39 - Warning bpbrm (pid=16033) from client inbmaster: WRN - Suspending further messages if reset access time fails
05/11/2015 13:57:11 - Error bptm (pid=16038) error requesting media, TpErrno = Robot operation failed
05/11/2015 13:57:11 - Warning bptm (pid=16038) media id 0061L1 load operation reported an error
05/11/2015 13:57:11 - current media 0061L1 complete, requesting next media Any
05/11/2015 13:57:15 - Info bptm (pid=16038) Waiting for mount of media id 0061L1 (copy 1) on server inbmaster.asicdesigners.com.
05/11/2015 13:57:15 - granted resource  0061L1
05/11/2015 13:57:15 - granted resource  IBM.ULT3580-HH4.000
05/11/2015 13:57:15 - granted resource  inbmaster-hcart-robot-tld-0
05/11/2015 13:57:15 - mounting 0061L1
05/11/2015 14:12:39 - Error bptm (pid=16038) error requesting media, TpErrno = Robot operation failed
05/11/2015 14:12:39 - Warning bptm (pid=16038) media id 0061L1 load operation reported an error
05/11/2015 14:12:42 - Info bptm (pid=16038) Waiting for mount of media id 0062L1 (copy 1) on server inbmaster.asicdesigners.com.
05/11/2015 14:12:39 - current media 0061L1 complete, requesting next media Any
05/11/2015 14:12:42 - granted resource  0062L1
05/11/2015 14:12:42 - granted resource  IBM.ULT3580-HH4.001
05/11/2015 14:12:42 - granted resource  inbmaster-hcart-robot-tld-0
05/11/2015 14:12:42 - end writing
05/11/2015 14:12:42 - mounting 0062L1
05/11/2015 14:28:16 - Error bptm (pid=16038) error requesting media, TpErrno = Robot operation failed
05/11/2015 14:28:16 - Warning bptm (pid=16038) media id 0062L1 load operation reported an error
05/11/2015 14:28:16 - current media 0062L1 complete, requesting next media Any
05/11/2015 14:28:49 - Error bptm (pid=16038) NBJM returned an extended error status: All compatible drive paths are down but media is available (2009)
05/11/2015 14:28:49 - Info bptm (pid=16038) EXITING with status 252 <----------
05/11/2015 14:28:50 - Error bpbrm (pid=16033) from client inbmaster: ERR - bpbkar exiting because backup is aborting
05/11/2015 14:28:50 - Info bpbkar (pid=16037) done. status: 252: extended error status has been encountered, check logs
05/11/2015 14:28:46 - current media -- complete, awaiting next media Any. Waiting for resources.
          Reason: Drives are in use, Media server: inbmaster.asicdesigners.com,
          Robot Type(Number): TLD(0), Media ID: N/A, Drive Name: N/A,
          Volume Pool: NetBackup, Storage Unit: inbmaster-hcart-robot-tld-0, Drive Scan Host: N/A,
          Disk Pool: N/A, Disk Volume: N/A
05/11/2015 14:28:50 - end writing
An extended error status has been encountered, check detailed status  (252)

Michael_G_Ander
Level 6
Certified

Are you sure that the tapes are LTO5 ? Normally they would have L5 as the last characters in the barcode.

Think you need to the check compatiblilty between the tape drives and the tapes.

Have you reconfigured the storage after changing tape drives ? (assume that is what you mean by changing tapes)

 

 

The standard questions: Have you checked: 1) What has changed. 2) The manual 3) If there are any tech notes or VOX posts regarding the issue

Marianne
Level 6
Partner    VIP    Accredited Certified
You cannot put LTO1 labels (L1) on LTO5 media. The robot sees the media as LTO1 and will not load the media in LTO5 drive.

sagar666
Level 5

Ok Making Up my drives and changing barcode seems resolve my prob right?

Thanks,

 

Michael_G_Ander
Level 6
Certified

Your tape drives does not seem to be configured as LTO5 which is  normally hcart2, but as either LTO1 or LTO4 as these normally shows up as hcart.

Besides that your tape drives need to be UP to be able to run backup.

Think you need to rescan the tapes drives in the OS and rerun Configure Storage Devices

 

The standard questions: Have you checked: 1) What has changed. 2) The manual 3) If there are any tech notes or VOX posts regarding the issue

Nicolai
Moderator
Moderator
Partner    VIP   

Using the right type of labels will definity help - but we can't say if there are others configurations errors.

Storage Unit density types need to be checked as well.

How new is this installation - brand new ?. Did you use the device configuratrion wizard ?

sagar666
Level 5

Hi,

I used device configuration wizard and configured.

I also make up the drives

Labeling L1 is worng for LTO5 tapes? we cant use LTO5 tapes with labeled with L1 at end. Since I have all barcodes printed with L1 at the end .

How configure tape drives? my LTO 5 tapes using hcart how to change to hcart2 for LTO5 tapes

Nicolai
Moderator
Moderator
Partner    VIP   

You are trying to bypass a security feature.

If it works using LTO1 labels with LTO5 tape and drives, is down to the firmware in the robot. It may reject mounting "LTO1" (LTO1 labeld LTO5 media) tapes in a LTO5 drive because LTO1 not compatible with LTO5 drives.

Buying a new set of LTO5 labels does not cost much - Please consider this.

 

HCART, HCART2, HCART3 is not related to LTO revisions. It is just a marker e.g red tapes for red tape drives, yellow for yellow. HCART2 tapes for HCART2 tape drives

Marianne
Level 6
Partner    VIP    Accredited Certified

Yes.

Labeling L1 is wrong for LTO5 tapes.

This has nothing to do with NBU, but with physical hardware compatibility.

Only LTO4 and LTO5 media (L4 and L5 labels) can be written by LTO5 drives.

If you put L1 labels on LTO5 media, the robot will see the tapes as LTO1 media.

You can see the robot error message if you bypass NBU and use robtest to try and load one of these tapes in LTO5 tape drive.