cancel
Showing results forΒ 
Search instead forΒ 
Did you mean:Β 

Unable to import disk Group - udid mismatch - label missing

hytham_fekry
Level 4
Partner Accredited Certified

Unable to import DG , Below is vxdisk list O/P :

DEVICE       TYPE           DISK        GROUP        STATUS               OS_NATIVE_NAME   ATTR        
disk_0       auto:none      -            -           online invalid       c0t5000CCA0251DB3C8d0s2 -            
disk_1       auto:none      -            -           online invalid       c0t5000CCA0251DCAE0d0s2 -            
disk_2       auto:none      -            -           online invalid       c0t5000CCA0251E4B84d0s2 -            
disk_3       auto:ZFS       -            -           ZFS                  c0t5000CCA0251E5D78d0s2 -            
emcpower0s2  auto           -            -           error udid_mismatch  emcpower0c       -            
emcpower1s2  auto:cdsdisk   -            (fdeappfmdev_dg) online thinrclm      emcpower1c       -            
emcpower2s2  auto           -            -           error udid_mismatch  emcpower2c       -            
emcpower3s2  auto:cdsdisk   -            (fdeappfmdev_dg) online thinrclm      emcpower3c       -            
emcpower4s2  auto:cdsdisk   -            (fdeappfmdev_dg) online thinrclm      emcpower4c       -            
emcpower5s2  auto:cdsdisk   -            (fdeappfmdev_dg) online thinrclm      emcpower5c       -            
emcpower6s2  auto           -            -           error udid_mismatch  emcpower6c       -            
emcpower7s2  auto:cdsdisk   -            (minotaurdbdev_dg) online thinrclm      emcpower7c       -            
emcpower8s2  auto:cdsdisk   -            (minotaurdbdev_dg) online thinrclm      emcpower8c       -            
emcpower9s2  auto:cdsdisk   -            (minotaurdbdev_dg) online thinrclm      emcpower9c       -            
emcpower10s2 auto:cdsdisk   -            (minotaurdbdev_dg) online thinrclm      emcpower10c      -            
emcpower11s2 auto           -            -           error udid_mismatch  emcpower11c      -            
emcpower12s2 auto:cdsdisk   -            (minotaurdbdev_dg) online               emcpower12c      -         

* vxdisk list for emcpower0 for instance  :

Device:    emcpower0s2
devicetag: emcpower0
type:      auto
flags:     error private autoconfig udid_mismatch
pubpaths:  block=/dev/vx/dmp/emcpower0s2 char=/dev/vx/rdmp/emcpower0s2
guid:      -
udid:      EMC%5FSYMMETRIX%5F000292601936%5F36033FF000
site:      -
Multipathing information:
numpaths:   1
emcpower0c    state=enabled

update the udid didn't work ,  These disks emcpower0 , emcpower2 ,   emcpower6 , emcpower11 are reporting the below errors in messages file  :

Jun  9 15:15:03 vienna scsi: [ID 107833 kern.warning] WARNING: /pci@400/pci@2/pci@0/pci@c/SUNW,emlxs@0/fp@0,0/ssd@w50000974081e41ac,8 (ssd13):
Jun  9 15:15:03 vienna     Corrupt label - bad geometry
Jun  9 15:15:03 vienna scsi: [ID 107833 kern.notice]     Label says 585921440 blocks; Drive says 536878080 blocks

SUN Explorer shows no label for theses LUNS , unlike other good LUNS "ex:emcpower12" ... LUNs are healthy from O.S. and storage side , No changes was done from storage side .. 

What Could be the reason , any suggesstion to solve this issue ?

2 REPLIES 2

RiaanBadenhorst
Moderator
Moderator
Partner    VIP    Accredited Certified

Think you should ask support. The fact that there is no GUID is a bit concerning. Usually a mismatch error whould show some type of ID which doesn't match the other ID, not nothing at all.

hytham_fekry
Level 4
Partner Accredited Certified

Thanks Riaan ..