We are about to deploy the

Gloria_Goode
Level 2

We are about to deploy the 8.04 EV client to prepare for 8.04 to 9.02 EV upgrade.  We are also using SCCM.  In testing, push calls for a reboot of the user's PC - some without notice.  I don't know if deployment team is using correct script.  Is there a switch we can use to suppress the reboot?

1 ACCEPTED SOLUTION

Accepted Solutions

TonySterling
Moderator
Moderator
Partner    VIP    Accredited Certified

Thanks mate,

Here was my reply

Hey Gloria,

They should probably use a /nostart or REBOOT=ReallySuppress.  One thing though, endusers will probably experience some issues until the reboot occurs.

Can they have it occur as part of a logout?  That way the end users won't be affected.

Tony
 

View solution in original post

3 REPLIES 3

JesusWept3
Level 6
Partner Accredited Certified

spawned this as a new discussion from here:
https://www-secure.symantec.com/connect/forums/silent-upgrade-ev-client-while-outlook-open

 

Tony Sterling has already answered however didnt want the old threads to keep updating for an already solved solution

https://www.linkedin.com/in/alex-allen-turl-07370146

TonySterling
Moderator
Moderator
Partner    VIP    Accredited Certified

Thanks mate,

Here was my reply

Hey Gloria,

They should probably use a /nostart or REBOOT=ReallySuppress.  One thing though, endusers will probably experience some issues until the reboot occurs.

Can they have it occur as part of a logout?  That way the end users won't be affected.

Tony
 

Gloria_Goode
Level 2

Hey, Tony.  It worked.  Tested with several individuals and got same results each time.  We're now ready to submit to change management group and deploy afterwards.  Thanks for your help.